ArticleJournal of orthopaedic surgery and research2023
Mechanical properties of an elastically deformable cervical spine implant.
Article in Journal of orthopaedic surgery and research, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 5 citations in OpenAlex.
- Potential Applications of Additive Manufacturing in Intervertebral Disc Replacement Using Gyroid Structures with Several Thermoplastic Polyurethane Filaments.Biomedicines · 2026Article
- Article
- The ability of SPEEK to promote the proliferation and osteogenic differentiation of BMSCs on PEEK surfaces.Heliyon · 2024Article
- On the suitability of additively manufactured gyroid structures and their potential use as intervertebral disk replacement - a feasibility study.Frontiers in bioengineering and biotechnology · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Anterior cervical surgery is widely accepted and time-tested surgical procedure for treating cervical radiculopathy and myelopathy. However, there is concern about the high adjacent segment degeneration rate and implant subsidence after the surgery using the traditional polyetheretherketone cage. Thus, we creatively designed a polyurethane cervical implant that can continuous load-sharing through elastic deformation and decrease postoperative stress concentration at adjacent segments. In this study, the design rationality and safety of this novel implant was evaluated based on several mechanical parameters including compression test, creeping test, push-out test and subsidence test. The results showed that the novel cervical implant remained intact under the compressive axial load of 8000 N and continues to maintained the elastic deformation phase. The minimum push-out load of the implant was 181.17 N, which was significantly higher than the maximum compressive shear load of 20 N experienced by a normal human cervical intervertebral disc. Besides, the creep recovery behaviour of the implant closely resembled what has been reported for natural intervertebral discs and clinically applied cervical devices in literature. Under the load of simulating daily activities of the cervical spine, the implant longitudinal displacement was only 0.54 mm. In conclusion, this study showed that the current design of the elastically deformable implant was reasonable and stable to fulfil the mechanical requirements of a cervical prosthesis under physiological loads. After a more comprehensive understanding of bone formation and stress distribution after implantation, this cervical implant is promising to be applied to certain patients in clinical practice.