Evidence map›Paper›PMID 37587439›Full record

ArticleBMC musculoskeletal disorders2023

Can ultrasound-guided radiofrequency ablation of genicular nerves of the knee, be performed without locating corresponding arterial pulsations-a cadaveric study.

Chinchu Kolakkanni, Nitesh Manohar Gonnade, Ravi Gaur, Ashish Kumar Nayyar, Rambeer Ghuleliya, Abins Tk

Open access · goldAbstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
2.5field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 8 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Review
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Chinchu KolakkanniDepartment of Physical Medicine and Rehabilitation, All India Institute of Medical Sciences, Phase 2 Basni, Jodhpur, Rajasthan, India, 342005.
Nitesh Manohar GonnadeDepartment of Physical Medicine and Rehabilitation, All India Institute of Medical Sciences, Phase 2 Basni, Jodhpur, Rajasthan, India, 342005. drniteshgonnade9@gmail.com.
Ravi GaurDepartment of Physical Medicine and Rehabilitation, All India Institute of Medical Sciences, Phase 2 Basni, Jodhpur, Rajasthan, India, 342005.
Ashish Kumar NayyarDepartment of Anatomy, All India Institute of Medical Sciences, Phase 2 Basni, Jodhpur, Rajasthan, India.
Rambeer GhuleliyaDepartment of Physical Medicine and Rehabilitation, All India Institute of Medical Sciences, Phase 2 Basni, Jodhpur, Rajasthan, India, 342005.
Abins TkDepartment of Physical Medicine and Rehabilitation, All India Institute of Medical Sciences, Phase 2 Basni, Jodhpur, Rajasthan, India, 342005.
All India Institute of Medical Sciences Jodhpur · INInstitute of Medical Sciences · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionGiven the rising prevalence of knee osteoarthritis, radiofrequency ablation of genicular nerves (RFA) has emerged as a promising treatment option for knee pain. The knee has an extremely complex and variable innervation with nearly 13 genicular nerves described. The frequently ablated genicular nerves are the superomedial (SMGN), the superolateral (SLGN), and the inferomedial (IMGN) genicular nerves. Conventionally, under ultrasound guidance, these nerves are ablated near the corresponding arterial pulsations, but due to the rich vascular anastomosis around the knee joint, identifying the arteries corresponding to these constant genicular nerves can be tedious unless guided by some bony landmarks. In this study, we have evaluated whether it is possible to accurately target these three genicular nerves by just locating bony landmarks under ultrasound in human cadaveric knee specimens.

methodsFifteen formalin-fixed cadaveric knee specimens were studied. SMGN was targeted 1 cm anterior to the adductor tubercle in the axial view. For SLGN, in the coronal view, the junction of the lateral femoral condyle and shaft was identified, and at the same level in the axial view, the crest between the lateral and posterior femoral cortex was targeted. For IMGN in the coronal view, the midpoint between the most prominent part of the medial tibial condyle and the insertion of the deep fibers of the medial collateral ligament was marked. The medial end of the medial tibial cortex was then targeted at the same level in the axial view. The needle was inserted from anterior to posterior, with an in-plane approach for all nerves. Eosin, 2% W/V, in 0.1 ml was injected. Microdissection was done while keeping the needle in situ. Staining of the nerve was considered a positive outcome, and the percentage was calculated. The nerve-to-needle distance was measured, and the mean with an interquartile range was calculated.

resultThe accuracies of ultrasound-guided bony landmarks of SMGN, SLGN, and IMGN were 100% in terms of staining, with average nerve-to-needle distances of 1.67, 3.2, and 1.8 mm respectively.

conclusionIt is with 100% accuracy, that we can perform RFA of SMGN, SLGN, and IMGN under ultrasound guidance, by locating the aforementioned bony landmarks.

Indexed as

ArteriesKnee JointCadaverFemurHumansUltrasonography, InterventionalBony landmarksGenicular nerveIMGNRadiofrequency ablation (RFA)SLGNSMGNUltrasound

Identifiers

PMID37587439
PMCPMC10429091
OpenAlexW4385877096

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.