Evidence map›Paper›PMID 37584681›Full record

ReviewRadiologie (Heidelberg, Germany)2024

Ultrahigh-field MRI: where it really makes a difference.

Siegfried Trattnig, Gilbert Hangel, Simon D Robinson, Vladimir Juras, Pavol Szomolanyi, Assunta Dal-Bianco

Erratum issuedOpen access · hybridAbstract readReview
In one paragraph

Review in Radiologie (Heidelberg, Germany), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.0field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Multi-center QA of ultrahigh-field systems.Magma (New York, N.Y.) · 2025
    Review
  3. Article
  4. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors at 1 institution in 2 countries.

Siegfried TrattnigHigh-Field MR Center - 7T MR, Department of Biomedical Imaging and Image-guided Therapy, Medical University Vienna, Lazarettgasse 14, 1090, Vienna, Austria. siegfried.trattnig@meduniwien.ac.at.
Gilbert HangelHigh-Field MR Center - 7T MR, Department of Biomedical Imaging and Image-guided Therapy, Medical University Vienna, Lazarettgasse 14, 1090, Vienna, Austria.
Simon D RobinsonHigh-Field MR Center - 7T MR, Department of Biomedical Imaging and Image-guided Therapy, Medical University Vienna, Lazarettgasse 14, 1090, Vienna, Austria.
Vladimir JurasHigh-Field MR Center - 7T MR, Department of Biomedical Imaging and Image-guided Therapy, Medical University Vienna, Lazarettgasse 14, 1090, Vienna, Austria.
Pavol SzomolanyiHigh-Field MR Center - 7T MR, Department of Biomedical Imaging and Image-guided Therapy, Medical University Vienna, Lazarettgasse 14, 1090, Vienna, Austria.
Assunta Dal-BiancoDepartment of Neurology, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria.
Medical University of Vienna · AT

Funding

Austrian Science Fund FWF KLI 917
6 · The paper itself

Abstract

backgroundCurrently, two major magnetic resonance (MR) vendors provide commercial 7‑T scanners that are approved by the Food and Drug Administration (FDA) for clinical application. There is growing interest in ultrahigh-field MRI because of the improved clinical results in terms of morphological detail, as well as functional and metabolic imaging capabilities. MATERIALS AND

methodsThe 7‑T systems benefit from a higher signal-to-noise ratio, which scales supralinearly with field strength, a supralinear increase in the blood oxygenation level dependent (BOLD) contrast for functional MRI and susceptibility weighted imaging (SWI), and the chemical shift increases linearly with field strength with consequently higher spectral resolution.

resultsIn multiple sclerosis (MS), 7‑T imaging enables visualization of cortical lesions, the central vein sign, and paramagnetic rim lesions, which may be beneficial for the differential diagnosis between MS and other neuroinflammatory diseases in challenging and inconclusive clinical presentations and are seen as promising biomarkers for prognosis and treatment monitoring. The recent development of high-resolution proton MR spectroscopic imaging in clinically reasonable scan times has provided new insights into tumor metabolism and tumor grading as well as into early metabolic changes that may precede inflammatory processes in MS. This technique also improves the detection of epileptogenic foci in the brain. Multi-nuclear clinical applications, such as sodium imaging, have shown great potential for the evaluation of repair tissue quality after cartilage transplantation and in the monitoring of newly developed cartilage regenerative drugs for osteoarthritis.

conclusionFor special clinical applications, such as SWI in MS, MR spectroscopic imaging in tumors, MS and epilepsy, and sodium imaging in cartilage repair, 7T may become a new standard.

Indexed as

Magnetic Resonance ImagingHumansMultiple Sclerosis7 TeslaMultiple sclerosisSodium imagingSpectroscopic imagingSusceptibility weighted imaging

Identifiers

PMID37584681
PMCPMC11602857
OpenAlexW4385850629

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.