Evidence map›Paper›PMID 37584531›Full record

ArticleACS sensors2023

Calibration-Free, Seconds-Resolved In Vivo Molecular Measurements using Fourier-Transform Impedance Spectroscopy Interrogation of Electrochemical Aptamer Sensors.

Brian Roehrich, Kaylyn K Leung, Julian Gerson, Tod E Kippin, Kevin W Plaxco, Lior Sepunaru

Open access · hybridAbstract read
In one paragraph

Article in ACS sensors, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
4.3field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 28 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Continuous, Week-Long, Seconds-ResolvedJournal of the American Chemical Society · 2026
    Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Review
  10. Review
  11. Article
  12. Article
  13. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Brian RoehrichDepartment of Chemistry and Biochemistry, University of California Santa Barbara, Santa Barbara, California 93106, United States.
Kaylyn K LeungDepartment of Chemistry and Biochemistry, University of California Santa Barbara, Santa Barbara, California 93106, United States.ORCID 0000-0002-8966-801X
Julian GersonDepartment of Psychological and Brain Sciences, University of California, Santa Barbara, California 93106, United States.
Tod E KippinDepartment of Psychological and Brain Sciences, University of California, Santa Barbara, California 93106, United States.
Kevin W PlaxcoDepartment of Chemistry and Biochemistry, University of California Santa Barbara, Santa Barbara, California 93106, United States.
Lior SepunaruDepartment of Chemistry and Biochemistry, University of California Santa Barbara, Santa Barbara, California 93106, United States.ORCID 0000-0002-4716-5035
University of California, Santa Barbara · US

Funding

Bio-electrochemical detectors for in vivo continuous monitoringR01EB022015 · NIBIB · UNIVERSITY OF CALIFORNIA SANTA BARBARA · PI KIPPIN, TOD EDWARD, PLAXCO, KEVIN W · 2017 to 2025
$4.6M
Bioelectrochemistry at the Nanoscale: Fundamentals and ApplicationsR35GM142920 · NIGMS · UNIVERSITY OF CALIFORNIA SANTA BARBARA · PI SEPUNARU, LIOR · 2021 to 2025
$1.7M
NIBIB NIH HHS R01 EB022015NIGMS NIH HHS R35 GM142920
6 · The paper itself

Abstract

Electrochemical aptamer-based (EAB) sensors are capable of measuring the concentrations of specific molecules in vivo, in real time, and with a few-second time resolution. For their signal transduction mechanism, these sensors utilize a binding-induced conformational change in their target-recognizing, redox-reporter-modified aptamer to alter the rate of electron transfer between the reporter and the supporting electrode. While a variety of voltammetric techniques have been used to monitor this change in kinetics, they suffer from various drawbacks, including time resolution limited to several seconds and sensor-to-sensor variation that requires calibration to remove. Here, however, we show that the use of fast Fourier transform electrochemical impedance spectroscopy (FFT-EIS) to interrogate EAB sensors leads to improved (here better than 2 s) time resolution and calibration-free operation, even when such sensors are deployed in vivo. To showcase these benefits, we demonstrate the approach's ability to perform real-time molecular measurements in the veins of living rats.

Indexed as

Aptamers, NucleotideBiosensing TechniquesAnimalsDielectric SpectroscopyElectrochemical TechniquesElectrodesRatsAptamers, Nucleotideaptamer sensorelectrochemical impedanceelectrochemical sensorfast-Fourier transformin vivo

Identifiers

PMID37584531
PMCPMC10463274
OpenAlexW4385851647

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.