Evidence map›Paper›PMID 37581062›Full record

ArticleQuantitative imaging in medicine and surgery2023

Quantitative analysis of contrast-enhanced ultrasonography in rat models of hepatic acute graft-versus-host disease.

Yuwei Xin, Yu Xiong, Feifei Liu, Linlin Qu, Wenxue Li, Li Yang, Yiqun Liu, Jia'an Zhu

Open access · diamondAbstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.2field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 4 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Yuwei Xin *Department of Ultrasound, Peking University People's Hospital, Beijing, China.
Yu Xiong *Department of Ultrasound, Peking University People's Hospital, Beijing, China.
Feifei LiuDepartment of Ultrasound, Peking University People's Hospital, Beijing, China.
Linlin QuDepartment of Pathology, Peking University People's Hospital, Beijing, China.
Wenxue LiDepartment of Ultrasound, Peking University People's Hospital, Beijing, China.
Li YangDepartment of Ultrasound, Peking University People's Hospital, Beijing, China.
Yiqun LiuDepartment of Ultrasound, Peking University People's Hospital, Beijing, China.
Jia'an ZhuDepartment of Ultrasound, Peking University People's Hospital, Beijing, China.
Peking University · CNBinzhou Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Hepatic acute graft-versus-host disease (aGVHD) is a major life-threatening complication of allogeneic hematopoietic stem cell transplantation (allo-HSCT). We hypothesized that contrast-enhanced ultrasound (CEUS) could serve as a new imaging biomarker in early diagnosis of hepatic aGVHD by detecting liver microcirculation. Methods: Thirty Wistar rats received allo-HSCT were finally included after excluding 9 rats, and they were randomly divided into 5 groups (1- to 5-week groups, 6 per group). Six rats were used for the control group without any intervention. We observed the clinical scores, serum liver enzyme levels and liver CEUS parameters of rats in each group. Hepatic aGVHD was finally confirmed by histopathologic analysis. The diagnostic performance of CEUS parameters in detecting GVHD was evaluated by comparing the area under the receiver operating curve (AUC) values. Results: After HSCT, the rats developed ruffling of fur, maculopapular rash, weight loss, accompanied by increased clinical scores. Serum liver enzymes were significantly higher than those in the control group from the third week, especially alkaline phosphatase, while CEUS parameters, peak intensity (PI) and mean transit time (MTT), changed in the second week (P<0.001). Compared with non-aGVHD group, the PI was significantly decreased while time to peak and MTT were prolonged in aGVHD group. CEUS parameters were more strongly correlated with pathological grade than serology. PI was an independent predictor for hepatic aGVHD. The AUC of CEUS parameters for diagnosing hepatic aGVHD was 0.933 (95% CI: 0.779-0.992), which was higher than that of clinical scores (AUC =0.748, 95% CI: 0.557-0.888, P=0.032) and serological markers (AUC =0.902, 95% CI: 0.737-0.980, P=0.694). Conclusions: CEUS exhibits promising applications as a quantitative method to detect hepatic aGVHD and early liver damage.

Indexed as

contrast-enhanced ultrasound (CEUS)Hematopoietic stem cell transplantation (HSCT)hepatic acute graft-versus-host disease (aGVHD)

Identifiers

PMID37581062
PMCPMC10423398
OpenAlexW4385525578

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.