Evidence map›Paper›PMID 37580843›Full record

ArticleRapid communications in mass spectrometry : RCM2023

A planar quadrupole device for transmitting and trapping ions in high vacuum.

Sung-Gun Park, Jared P Mohr, Gordon A Anderson, James E Bruce

Abstract read
In one paragraph

Article in Rapid communications in mass spectrometry : RCM, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Sung-Gun ParkDepartment of Genome Sciences, University of Washington, Seattle, Washington.
Jared P MohrDepartment of Genome Sciences, University of Washington, Seattle, Washington.
Gordon A AndersonGAA Custom Electronics, LLC, Kennewick, Washington.
James E BruceDepartment of Genome Sciences, University of Washington, Seattle, Washington.ORCID https://orcid.org/0000-0001-6441-6089

Funding

Dynamics of the cellular interactomeR35GM136255 · NIGMS · UNIVERSITY OF WASHINGTON · PI James Edward Bruce · 2020 to 2026
$4.0M
The heart failure interactomeR01HL144778 · NHLBI · UNIVERSITY OF WASHINGTON · PI BRUCE, JAMES EDWARD · 2019 to 2022
$2.7M
Aging Mitochondrial InteractomeR01AG078279 · NIA · UNIVERSITY OF WASHINGTON · PI James Edward Bruce, David J. Marcinek · 2023 to 2026
$2.2M
Structure-function changes in the mitochondrial interactome with ageR56AG070096 · NIA · UNIVERSITY OF WASHINGTON · PI BRUCE, JAMES EDWARD, MARCINEK, DAVID J. · 2021 to 2021
$362k
Aging Mitochondrial InteractomeR56AG078279 · NIA · UNIVERSITY OF WASHINGTON · PI BRUCE, JAMES EDWARD, MARCINEK, DAVID J. · 2022 to 2022
$361k
NHLBI NIH HHS R01 HL144778NIA NIH HHS R01 AG078279NIA NIH HHS R56 AG070096NIA NIH HHS R56 AG078279NIGMS NIH HHS R35 GM136255NIH HHS R01AG078279NIH HHS R01HL144778NIH HHS R35GM136255NIH HHS R56AG070096NIH HHS R56AG078279
6 · The paper itself

Abstract

rationaleHybrid mass spectrometers combine multiple mass analyzers to achieve optimal performance in terms of tandem mass spectrometry, high mass resolving power, and mass measurement accuracy for studying highly complex samples. As a result, the need for transport, trapping, and control of ion kinetic energies is critical for the successful integration of multiple mass analyzers and hybrid instrument operation. In addition, transportation of ion populations between two physically distinct locations can result in time-of-flight (TOF) discrimination against ions with widely disparate m/z values, compromising full mass spectral performance. In this work, we demonstrated a new ion guide, referred to as a planar quadrupole (PQ) ion guide, composed of two parallel printed circuit boards (PCB) that allow radiofrequency (RF) and direct current (DC) voltages to be combined to enable both axial transport and trapping of ion populations in the ultrahigh vacuum region of the mass spectrometer. As compared with a conventional multipole ion guide, the PQ ion guide showed comparable performance in ion m/z values, signal-to-noise, and intensity and effectively reduced mass discrimination caused by TOF effects.

methodsA PQ device was developed with two PCBs and simulated with SIMION 8.1. Electrospray ionization and Fourier transform ion cyclotron resonance mass spectrometry instrumentation were used for the testing of PQ performance.

results.In this work, we demonstrated a planar quadrupole (PQ) ion guide composed of two parallel PCB plates. The PQ enables both axial ion transport and trapping of ion populations throughout the ion transfer process from a LTQ to an ICR cell. As compared with a conventional multipole ion guide, the PQ showed comparable ion transmission efficiency and effectively reduced mass discrimination caused by TOF effects.

conclusionsThe PQ is a simple design that can be implemented for ion transmission and trapping on virtually any mass spectrometer.

Identifiers

PMID37580843
PMCPMC11867028

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.