Evidence map›Paper›PMID 37580424›Full record

ArticleCardiovascular and interventional radiology2023

Safety and Feasibility of Gun-Sight Technique for Transjugular Intra-hepatic Portosystemic Shunt (TIPS) Creation.

Nathan Elie Frenk, Taedo Jake Choi, Lauren Sunhye Park, Emil Israel Cohen, George Emmet Lynskey, Saher Salim Sabri

Abstract readMulticenter Study
PubMed Publisher
In one paragraph

Article in Cardiovascular and interventional radiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Interventions in Budd-Chiari syndrome: an updated review.Abdominal radiology (New York) · 2025
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Nathan Elie FrenkDivision of Interventional Radiology, Department of Radiology, MedStar Georgetown University Hospital, 3800 Reservoir Rd NW, Washington, DC, 20007, USA. nathanfrenk@gmail.com.ORCID http://orcid.org/0000-0001-5995-9409
Taedo Jake ChoiDivision of Interventional Radiology, Department of Radiology, MedStar Georgetown University Hospital, 3800 Reservoir Rd NW, Washington, DC, 20007, USA.ORCID http://orcid.org/0000-0003-1914-7216
Lauren Sunhye ParkDivision of Interventional Radiology, Department of Radiology, MedStar Georgetown University Hospital, 3800 Reservoir Rd NW, Washington, DC, 20007, USA.ORCID http://orcid.org/0000-0002-8384-2785
Emil Israel CohenDivision of Interventional Radiology, Department of Radiology, MedStar Georgetown University Hospital, 3800 Reservoir Rd NW, Washington, DC, 20007, USA.ORCID http://orcid.org/0000-0001-8678-8916
George Emmet LynskeyDivision of Interventional Radiology, Department of Radiology, MedStar Georgetown University Hospital, 3800 Reservoir Rd NW, Washington, DC, 20007, USA.ORCID http://orcid.org/0000-0002-7390-695X
Saher Salim SabriDivision of Interventional Radiology, Department of Radiology, MedStar Georgetown University Hospital, 3800 Reservoir Rd NW, Washington, DC, 20007, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo review technical details, indications for use, success rates and complications of gun-sight technique for transjugular intra-hepatic portosystemic shunt (TIPS) creation. MATERIALS AND

methodsA multicenter retrospective review was performed. Forty-two TIPS procedures with gun-sight technique were identified between 2016 and 2021. Eighty-six percent of patients had portal vein thrombosis (PVT), and 21% had undergone prior failed TIPS creation. Demographics, procedure details and outcomes were reviewed. Differences between the groups, event rates and patency rates were evaluated using nonparametric two-sample Wilcoxon rank-sum (Mann-Whitney) test, Fisher's exact test, Kaplan-Meier curves, and log-rank test.

resultsTechnical success was 98%. Sixty-seven percent of subjects had transsplenic and 26% had transhepatic access for TIPS creation. Twenty-one adverse events were noted (48%), four of which were definitely related and four were probably related to the use of gun-sight technique. Early (within 90 days) thrombosis occurred in 7/41 patients (17%), all of whom had existing PVT.

conclusionGun-sight technique for TIPS creation has a high success rate in this challenging cohort of patients. While complications can occur, most of the adverse events noted were likely associated with TIPS creation itself rather than gun-sight. Early thrombosis only occurred in patients with PVT. Level of Evidence Level 4, Case Series.

Indexed as

Portasystemic Shunt, Transjugular IntrahepaticThrombosisVenous ThrombosisFeasibility StudiesHumansPortal VeinRetrospective StudiesTreatment Outcomegun-sightportal vein thrombosisTIPSTransjugular intra-hepatic portosystemic shunt

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.