Evidence map›Paper›PMID 37579768›Full record

ArticlePhysics in medicine and biology2023

Colored reflectors to improve coincidence timing resolution of BGO-based time-of-flight PET detectors.

Daehee Lee, Simon R Cherry, Sun Il Kwon

Abstract read
In one paragraph

Article in Physics in medicine and biology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Timing Performance with Broadcom Metal Trench Silicon Photomultipliers.IEEE transactions on radiation and plasma medical sciences · 2025
    Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Daehee LeeDepartment of Biomedical Engineering, University of California, Davis, Davis, CA 95616, United States of America.
Simon R CherryDepartment of Biomedical Engineering, University of California, Davis, Davis, CA 95616, United States of America.
Sun Il KwonDepartment of Biomedical Engineering, University of California, Davis, Davis, CA 95616, United States of America.ORCID 0000-0002-1810-2123

Funding

Research at the interface of optical and ionizing radiation for innovative cancer imaging and therapyR35CA197608 · NCI · UNIVERSITY OF CALIFORNIA AT DAVIS · PI CHERRY, SIMON R · 2015 to 2021
$4.9M
Time-of-flight positron emission tomography using Cerenkov luminescence in bismuth germanateR01EB029633 · NIBIB · UNIVERSITY OF CALIFORNIA AT DAVIS · PI KWON, SUN IL · 2020 to 2024
$1.6M
NCI NIH HHS R35 CA197608NIBIB NIH HHS R01 EB029633
6 · The paper itself

Abstract

Time-of-flight (TOF) positron emission tomography (PET) detectors improve the signal-to-noise ratio of PET images by limiting the position of the generation of two 511 keV gamma-rays in space using the arrival time difference between the two photons. Unfortunately, bismuth germanate (BGO), widely used in conventional PET detectors, was limited as a TOF PET scintillator due to the relatively slow decay time of the scintillation photons. However, prompt Cerenkov light in BGO has been identified in addition to scintillation photons. Using Cerenkov photons for timing has significantly improved the coincidence timing resolution (CTR) of BGO. Based on this, further research on improving the CTR for a BGO-based TOF PET system is being actively conducted. Wrapping materials for BGO pixels have primarily employed white reflectors to most efficiently collect scintillation light. White reflectors have customarily been used as reflectors for BGO pixels even after Cerenkov light began to be utilized for timing calculations in pixel-level experiments. However, when the arrival-time differences of the two 511 keV annihilations photons were measured with pure Cerenkov radiators, painting the lateral sides of the radiators black can improve CTR by suppressing the reflection of Cerenkov photons. The use of BGO for TOF PET detectors requires simultaneously minimizing scintillation loss for good energy information and suppressing reflected Cerenkov photons for better timing performance. Thus, reflectors for BGO pixels should be optimized for better timing and energy performance. In this study, colored polytetrafluoroethylene (PTFE) tapes with discontinuous reflectance values at specific wavelengths were applied as a BGO reflector. We hypothesized that CTR could be enhanced by selectively suppressing reflected Cerenkov photons with an optimum colored reflector on the BGO pixel while minimizing scintillation photon loss. CTRs were investigated utilizing white and three colors (yellow, red, and green) PTFE tapes as a reflector. In addition, black-painted PTFE tape and enhanced specular reflector film were investigated as reference reflector materials. When 3 × 3 × 20 mm

Indexed as

Positron-Emission TomographyScintillation CountingGamma RaysPhotonsbismuth germanate (BGO)Cerenkov (Cherenkov)discontinuous reflectionenhanced specular reflector (ESR) filmreflectortime-of-flight positron emission tomography (TOF PET)

Identifiers

PMID37579768
PMCPMC10722960

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked