Evidence map›Paper›PMID 37579138›Full record

ArticleProceedings of the National Academy of Sciences of the United States of America2023

Near-infrared voltage-sensitive dyes based on chromene donor.

Ping Yan, Corey D Acker, Valentina Biasci, Giuliana Judge, Alexa Monroe, Leonardo Sacconi, Leslie M Loew

Open access · greenAbstract read
In one paragraph

Article in Proceedings of the National Academy of Sciences of the United States of America, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.9field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 3 countries.

Ping YanRichard D. Berlin Center for Cell Analysis and Modeling, University of Connecticut Health Center, Farmington, CT 06030.ORCID 0000-0001-6472-150X
Corey D AckerRichard D. Berlin Center for Cell Analysis and Modeling, University of Connecticut Health Center, Farmington, CT 06030.
Valentina BiasciEuropean Laboratory for Non-Linear Spectroscopy, University of Florence, Sesto Fiorentino 50019, Italy.
Giuliana JudgeRichard D. Berlin Center for Cell Analysis and Modeling, University of Connecticut Health Center, Farmington, CT 06030.ORCID 0009-0002-9474-8329
Alexa MonroeRichard D. Berlin Center for Cell Analysis and Modeling, University of Connecticut Health Center, Farmington, CT 06030.
Leonardo SacconiInstitute of Clinical Physiology, National Research Council, Florence 50139, Italy.ORCID 0000-0002-9320-5085
Leslie M LoewRichard D. Berlin Center for Cell Analysis and Modeling, University of Connecticut Health Center, Farmington, CT 06030.ORCID 0000-0002-1851-4646
UConn Health · USUniversity of Florence · ITUniversity of Freiburg · DE

Funding

Improved Ratiometric Voltage-Sensitive Dyes for In-Vitro and In-Vivo Imaging of Brain Electrical SignalingR43MH121236 · NIMH · POTENTIOMETRIC PROBES, LLC · PI ACKER, COREY · 2019 to 2020
$450k
High sensitivity tethered bichromophoric voltage-sensitive dyesR43MH116830 · NIMH · POTENTIOMETRIC PROBES, LLC · PI ACKER, COREY · 2018 to 2018
$225k
NIMH NIH HHS R43 MH116830NIMH NIH HHS R43 MH121236
6 · The paper itself

Abstract

Voltage-sensitive dyes (VSDs) are used to image electrical activity in cells and tissues with submillisecond time resolution. Most of these fast sensors are constructed from push-pull chromophores whose fluorescence spectra are modulated by the electric field across the cell membrane. It was found that the substitution of naphthalene with chromene produces a 60 to 80 nm red-shift in absorption and emission spectra while maintaining fluorescence quantum efficiency and voltage sensitivity. One dye was applied to ex vivo murine heart with excitation at 730 nm, by far the longest wavelength reported in voltage imaging. This VSD resolves cardiac action potentials in single trials with 12% ΔF/F per action potential. The well-separated excitation spectra between these long-wavelength VSDs and channelrhodopsin (ChR2) enabled monitoring of action potential propagation in ChR2 hearts without any perturbation of electrical dynamics. Importantly, by employing spatially localized optogenetic manipulation, action potential dynamics can be assessed in an all-optical fashion with no artifact related to optical cross-talk between the reporter and actuator. These new environmentally sensitive chromene-based chromophores are also likely to have applications outside voltage imaging.

Indexed as

Fluorescent DyesHeartAction PotentialsAnimalsFluorescenceMiceFluorescent Dyescardiac electrophysiologyfluorescencemicroscopyvoltage-sensitive dyes

Identifiers

PMID37579138
PMCPMC10450434
OpenAlexW4385802939

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.