Evidence map›Paper›PMID 37577320›Full record

ArticleTranslational lung cancer research2023

Diagnostic accuracy and safety of electromagnetic navigation transthoracic needle biopsy under moderate sedation for the diagnosis of peripheral pulmonary lesions.

SoJeong Kim, NaYoung Kim, SooJie Chung, JungHyun Kim, InGyu Hyun, JeongHee Choi, HeeSung Lee

Open access · diamondAbstract read
In one paragraph

Article in Translational lung cancer research, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.3field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

SoJeong KimDivision of Pulmonary, Allergy and Critical Care Medicine, Department of Internal Medicine, Hallym University Dongtan Sacred Heart Hospital, Hwaseong, Republic of Korea.
NaYoung KimDivision of Pulmonary, Allergy and Critical Care Medicine, Department of Internal Medicine, Hallym University Dongtan Sacred Heart Hospital, Hwaseong, Republic of Korea.
SooJie ChungDivision of Pulmonary, Allergy and Critical Care Medicine, Department of Internal Medicine, Hallym University Dongtan Sacred Heart Hospital, Hwaseong, Republic of Korea.
JungHyun KimDivision of Pulmonary, Allergy and Critical Care Medicine, Department of Internal Medicine, Hallym University Dongtan Sacred Heart Hospital, Hwaseong, Republic of Korea.
InGyu HyunDivision of Pulmonary, Allergy and Critical Care Medicine, Department of Internal Medicine, Hallym University Dongtan Sacred Heart Hospital, Hwaseong, Republic of Korea.
JeongHee Choi *Division of Pulmonary, Allergy and Critical Care Medicine, Department of Internal Medicine, Hallym University Dongtan Sacred Heart Hospital, Hwaseong, Republic of Korea.
HeeSung Lee *Department of Thoracic and Cardiovascular Surgery, Hallym University Dongtan Sacred Heart Hospital, Hwaseong, Republic of Korea.
Hallym University Dongtan Sacred Heart Hospital · KRHallym University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Novel approaches using virtual computed tomography (CT) guidance, namely electromagnetic navigation transthoracic needle biopsy (EMN-TTNB), enable physicians to perform percutaneous lung biopsies. However, there are very few studies on the clinical experiences of EMN-TTNB, and in previous studies, the procedure was usually performed under deep sedation. This study aimed to determine the diagnostic accuracy and safety of EMN-TTNB under moderate sedation. Methods: We conducted a retrospective analysis of patients who underwent EMN-TTNB under moderate sedation between May 2021 and November 2022 at Hallym University Dongtan Sacred Heart Hospital in South Korea. Moderate sedation was achieved with midazolam injection in the bronchoscopy room using the Veran SPiNperc EM guidance system (Veran Medical, St Louis, MO, USA). Clinical data were collected by review of medical records, and diagnostic accuracy and safety were calculated. Results: Thirty-two patients were enrolled (mean age 70.8±11.1 years); 56.3% were male. The mean size of the pulmonary lesions was 36.9±17.4 mm, and the median (interquartile range) distance from the pleura was 15.5 (0.0-30.0) mm. The diagnostic accuracy of EMN-TTNB was 75.0% (21/28), excluding four indeterminate cases. Fourteen patients (50.0%, 14/28) had true-positive and seven patients (25.0%, 7/28) had true-negative lesions. There were no severe adverse reactions such as pneumothorax, respiratory failure, or death, except one case of hemoptysis. Conclusions: EMN-TTNB under moderate sedation showed an acceptable diagnostic accuracy and good safety profile. The new technology allows physicians to perform percutaneous lung biopsies without the intervention of a radiologist or anesthesiologist.

Indexed as

diagnostic accuracyElectromagnetic navigation transthoracic needle biopsy (EMN-TTNB)moderate sedationpulmonary lesionsafety

Identifiers

PMID37577320
PMCPMC10413044
OpenAlexW4385306215

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.