ArticleCureus2023
Comparison of the Efficacy of Light's Criteria With Serum-Effusion Albumin Gradient and Pleural Effusion Glucose.
Article in Cureus, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 5 citations in OpenAlex.
- Article
- High diagnostic accuracy of flexible thoracoscopy for distinguishing tuberculous from malignant pleural effusions.American journal of translational research · 2025Article
- Article
- Measurement of Feline Alpha-1 Acid Glycoprotein in Serum and Effusion Using an ELISA Method: Analytical Validation and Diagnostic Role for Feline Infectious Peritonitis.Pathogens (Basel, Switzerland) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction While Light's criteria exhibit high sensitivity (98%) in detecting exudative pleural effusions, the capacity to rule out transudates is relatively limited. A previous study showed that approximately one-fifth of patients with congestive cardiac failure on diuretics also met the criteria for exudate. This study compares the diagnostic value of Light's criteria, the serum-effusion albumin gradient (SEAG) method, and pleural effusion glucose levels for accurately categorizing pleural effusion as transudate or exudate. Methodology We conducted this cross-sectional observational study in a tertiary care hospital in Ahmedabad, India. Two hundred patients with pleural effusion undergoing thoracentesis were included. Laboratory parameters measured in pleural fluid analysis included pleural fluid protein, pleural fluid lactate dehydrogenase (LDH), pleural fluid albumin, and pleural fluid glucose. Serum protein, serum LDH, and serum albumin were also collected. Mean values and standard deviations (SDs) were calculated for analysis. Results A significant difference was observed in the mean value of exudative and transudative effusions for each parameter (pleural fluid protein/serum fluid protein ratio, pleural fluid LDH/serum fluid LDH ratio, pleural fluid LDH, SEAG, and pleural fluid glucose) (P < 0.001). Light's criteria demonstrated the highest efficacy in diagnosing exudates (accuracy = 97.50%), while SEAG demonstrated the highest efficacy in diagnosing transudates (accuracy = 97.50%). Conclusion SEAG is an effective alternative diagnostic tool for identifying transudates misclassified by Light's criteria. Its use can contribute to prompt diagnosis and timely treatment of patients with pleural effusion, improving patient outcomes.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.