ArticleJournal of medical physics
Evaluation of In-room Volumetric Imaging Doses for Image-guided Radiotherapy: A Multi-institutional Study.
Article in Journal of medical physics. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Imaging dose in image-guided radiotherapy for localized prostate intensity-modulated radiotherapy: a nationwide survey in Japan.Journal of radiation research · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Aims: We investigated imaging dose and noise under clinical scan conditions at multiple institutions using a simple and unified method, and demonstrated the need for diagnostic reference levels in image-guided radiotherapy (IGRT). Materials and Methods: Nine cone-beam and helical computed tomography (CT) scanners (Varian, Elekta, Accuray Inc., and BrainLAB) from seven institutions were investigated in this study. The weighted cone-beam dose index (CBDI Results: For head and pelvic protocols, CBDI Conclusions: Among the nine machines, the imaging dose for high imaging dose institutions was approximately 20 mGy to the pelvic phantom, and there was a 14-fold difference in dose compared with the other institutions. These results suggest the need to establish DRLs for IGRT to guide clinical decision-making.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials