Evidence map›Paper›PMID 37575823›Full record

ArticleCureus2023

An Evaluation of the Effectiveness of Various Luting Cements on the Retention of Implant-Supported Metal Crowns.

Surbhi Mehta, Anubhav Kesari, Mohit Tomar, Urvashi Sharma, Preeti Sagar, Pooja Nakum, Kumuda Rao

Abstract read
In one paragraph

Article in Cureus, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Surbhi MehtaProsthodontics and Crown & Bridge, Inderprastha Dental College & Hospital, Ghaziabad, IND.
Anubhav KesariProsthodontics and Crown & Bridge, Subharti Dental College, Meerut, IND.
Mohit TomarProsthodontics and Crown & Bridge, Inderprastha Dental College & Hospital, Ghaziabad, IND.
Urvashi SharmaProsthodontics and Crown & Bridge, Smile Carve Dental Clinic, Jaipur, IND.
Preeti SagarProsthodontics and Crown & Bridge, Homi Bhabha Cancer Hospital & Research Center-Muzaffarpur (A Unit of Tata Memorial Hospital, Mumbai), Muzaffarpur, IND.
Pooja NakumOral Surgery, Goenka Research Institute of Dental Science, Gandhinagar, IND.
Kumuda RaoOral Medicine and Radiology, AB Shetty Memorial Institute of Dental Sciences - Nitte (Deemed to be University), Mangalore, IND.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and objective Cement-retained prostheses have replaced screw-retained prostheses as the preferred restoration in recent years in order to overcome the latter's limitations. In this study, four different luting cements were compared to evaluate their efficacy on the retention of cement-based metal crowns to implant abutments. Materials and methods In the right and left first molar regions, four implant analogs (Internal Hex, Adin Dental Implant Systems Ltd., Tel-Aviv, Israel) were screwed into epoxy resin casts (Araldite CY 230-1 IN, India) that were positioned perpendicular to the cast's plane. Four metal copings were created and cemented. Group A: polycarboxylate cement (DUR) (DurelonTM, 3M Espe, St. Paul, MN); Group B: PANAVIA™ F 2.0 dual-cure resin cement (Kuraray America, Inc., New York, NY); Group C: resin-modified glass ionomer (3M™ RelyX™ Luting, 3M Espe); and Group D: non-eugenol temporary resin cement (Kerr-Temp, KaVo Kerr, Brea, CA) were used to cement crowns. To check the retention capacity, samples were put through a pull-out test on an Instron universal testing machine (TSI‑Tecsol, Bengaluru, India) with a crosshead speed of 0.5 mm/min. Each coping's de-cementing load was noted, and average values for every sample were computed and statistically analyzed. Results The findings demonstrated that non-eugenol temporary resin implant cement has the lowest retention value at 138.256 N, followed by resin-modified glass ionomer cement at 342.063 N, polycarboxylate luting cement at 531.362 N, and resin cement at 674.065 N. The average difference in retentive strength across all four groups was statistically very significant (p=0.001). Conclusion Based on our findings, non-eugenol temporary resin implant cement enables simple retrievability of the prosthesis in the event of a future failure and is appropriate for implant restorations with cement retention. Also, cements made of polycarboxylate and resin have the highest retention values.

Indexed as

cementimplantlutingresin cementretention test

Identifiers

PMID37575823
PMCPMC10413795

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.