Evidence map›Paper›PMID 37575712›Full record

ArticleCureus2023

Influence of Windowing and Evaluation of Metal Artifact Reduction Algorithm on Five Different Restorative Materials by Using Different Cone Beam Computed Tomography (CBCT) Scanners: A CBCT Study.

Ajay Sutare, Ajay Parihar, Prashanthi Reddy, Renu Singh, Varsha Ac

Abstract read
In one paragraph

Article in Cureus, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Ajay SutareDepartment of Oral Medicine and Radiology, Government College of Dentistry Indore, Indore, IND.
Ajay PariharDepartment of Oral Medicine and Radiology, Government College of Dentistry Indore, Indore, IND.
Prashanthi ReddyDepartment of Oral Medicine and Radiology, Government College of Dentistry Indore, Indore, IND.
Renu SinghDepartment of Oral Medicine and Radiology, Government College of Dentistry Indore, Indore, IND.
Varsha AcDepartment of Oral Medicine and Radiology, Government College of Dentistry Indore, Indore, IND.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo assess the influence of windowing, and to evaluate, and compare the effect of the metal artifact reduction (MAR) and non-metal artifact reduction (non-MAR) algorithms on different high-density restorative dental materials using different cone beam computed tomography (CBCT) devices. MATERIAL AND

methodHeight and diameter of all cylindrical shape metals including amalgam, cobalt-chromium, composite, gutta-percha, and titanium were measured using a digital caliper device. Polymethylmethacrylate block and arch phantom with a cylindrical-shaped perforation containing five different metals were submitted to tomographic acquisition with six different cone beam computed tomographic devices in small fields of view with their MAR enabled and disabled. Windowing was done using ITK-SNAP software (3.8.2) which was used as a contrast medial tool for window level and window width. The data was analyzed for probability distribution using the Kolmogorov-Smirnov test, where a p-value of <0.05 indicated that the data were not normally distributed. The comparison of length and width was done using the Wilcoxon sign rank test. Comparison of categorical variables was done using the Chi-square test where a p-value of <0.05 was considered statistically significant.

resultsLength and width of all these metals measured using MAR and non-MAR CBCT were found to be statistically non-significant (p-value of >0.05). MAR algorithm significantly reduces metals artifact produced by high-density restorative materials (p-value of <0.05).

conclusionAmalgam and cobalt-chromium produced more artifacts while composite and gutta-percha did not produce enough artifacts to be reduced by the MAR algorithm. Large window width and high window level would be beneficial to reduce the metal artifact.

Indexed as

algorithmartifact reductioncone-beam conventional tomography (cbct)metallic artifactrestorative dental materials

Identifiers

PMID37575712
PMCPMC10415591

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.