Evidence map›Paper›PMID 37575672›Full record

ArticlePNAS nexus2023

Short-wave infrared fluorescence imaging of near-infrared dyes with robust end-tail emission using a small-animal imaging device.

Francesca Arena, Francesca La Cava, Daniele Faletto, Miriam Roberto, Federico Crivellin, Francesco Stummo, Alessia Adamo, Mariangela Boccalon, Roberta Napolitano, Francesco Blasi and 3 more

Open access · goldAbstract read
In one paragraph

Article in PNAS nexus, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.7field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors at 2 institutions in 1 country.

Francesca ArenaBracco Research Center, Bracco Imaging S.p.A., Turin 10010, Italy.ORCID https://orcid.org/0000-0003-3644-0609
Francesca La CavaBracco Research Center, Bracco Imaging S.p.A., Turin 10010, Italy.ORCID https://orcid.org/0000-0002-7722-557X
Daniele FalettoBracco Research Center, Bracco Imaging S.p.A., Turin 10010, Italy.
Miriam RobertoMolecular Imaging Center, Department of Molecular Biotechnologies and Health Sciences, University of Torino, Turin 10126, Italy.ORCID https://orcid.org/0000-0002-3804-5031
Federico CrivellinBracco Research Center, Bracco Imaging S.p.A., Turin 10010, Italy.
Francesco StummoBracco Research Center, Bracco Imaging S.p.A., Turin 10010, Italy.ORCID https://orcid.org/0009-0007-2643-8851
Alessia AdamoBracco Research Center, Bracco Imaging S.p.A., Turin 10010, Italy.
Mariangela BoccalonBracco Research Center, Bracco Imaging S.p.A., Turin 10010, Italy.ORCID https://orcid.org/0000-0002-1430-3534
Roberta NapolitanoBracco Research Center, Bracco Imaging S.p.A., Turin 10010, Italy.
Francesco BlasiBracco Research Center, Bracco Imaging S.p.A., Turin 10010, Italy.
Maximilian KochSurgVision GmbH, Munich 81379, Germany.
Adrian TaruttisSurgVision GmbH, Munich 81379, Germany.
Erika ReitanoSurgVision GmbH, Munich 81379, Germany.ORCID https://orcid.org/0009-0008-0038-4768
Bracco (Italy) · ITUniversity of Turin · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Commercially available near-infrared (NIR) dyes, including indocyanine green (ICG), display an end-tail of the fluorescence emission spectrum detectable in the short-wave infrared (SWIR) window. Imaging methods based on the second NIR spectral region (1,000-1,700 nm) are gaining interest within the biomedical imaging community due to minimal autofluorescence and scattering, allowing higher spatial resolution and depth sensitivity. Using a SWIR fluorescence imaging device, the properties of ICG vs. heptamethine cyanine dyes with emission >800 nm were evaluated using tissue-simulating phantoms and animal experiments. In this study, we tested the hypothesis that an increased rigidity of the heptamethine chain may increase the SWIR imaging performance due to the bathochromic shift of the emission spectrum. Fluorescence SWIR imaging of capillary plastic tubes filled with dyes was followed by experiments on healthy animals in which a time series of fluorescence hindlimb images were analyzed. Our findings suggest that higher spatial resolution can be achieved even at greater depths (>5 mm) or longer wavelengths (>1,100 nm), in both tissue phantoms and animals, opening the possibility to translate the SWIR prototype toward clinical application.

Indexed as

biomedical imagingdeep-tissue imaginghindlimb vasculatureprincipal component analysisshort-wave infrared imaging

Identifiers

PMID37575672
PMCPMC10422693
OpenAlexW4385456603

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.