ReviewVideoGIE : an official video journal of the American Society for Gastrointestinal Endoscopy2023
Endoscopic Resection Techniques for Duodenal and Ampullary Adenomas.
Review in VideoGIE : an official video journal of the American Society for Gastrointestinal Endoscopy, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06435533 (Cold Atmospheric Plasma for the Endoscopic Treatment of Duodenal Polyps in Patients With Familial Adenomatous Polyposis), which is not on this map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Cold Atmospheric Plasma for the Endoscopic Treatment of Duodenal Polyps in Patients With Familial Adenomatous Polyposis
Who cites it
8 citing papers in PubMed, 9 citations in OpenAlex.
- Histopathologic discrepancies between endoscopic forceps biopsy and resection specimens in duodenal papillary lesions: a retrospective study.BMC gastroenterology · 2025Observational
- Article
- Progress in the treatment of duodenal cancer: A comprehensive review.World journal of gastrointestinal oncology · 2025Review
- Endoscopic Management of Ampullary Adenomas: A Comprehensive Review.Journal of clinical medicine · 2025Review
- Factors associated with delayed bleeding following ampullectomy: A retrospective cohort study.DEN open · 2025Article
- Novel use of endoscopic morcellation of a duodenal bulb polyp.VideoGIE : an official video journal of the American Society for Gastrointestinal Endoscopy · 2025Article
- Endoscopic full-thickness resection as a cure for recurrent duodenal adenoma.iGIE : innovation, investigation and insights · 2023Article
- [Biodegradable Pancreatic Stent in Endoscopic Resection of an Ampulloma in Argentina: A Case Report].Acta gastroenterologica LatinoamericanaArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background and Aims: Duodenal polyps have a reported incidence of 0.3% to 4.6%. Sporadic, nonampullary duodenal adenomas (SNDAs) comprise less than 10% of all duodenal polyps, and ampullary adenomas are even less common. Nonetheless, the incidence continues to rise because of widespread endoscopy use. Duodenal polyps with villous features or those that are larger than 10 mm may raise concern for malignancy and require removal. We demonstrate endoscopic resection of SNDAs and ampullary adenomas using some of our preferred techniques. Methods: The duodenum has several components that can make EMR of duodenal polyps technically challenging. Not only does the duodenum have a thin muscle layer, but it is also highly mobile and vascular, which may explain higher rates of perforation and bleeding of duodenal EMR reported in the literature compared with colon EMR. A standard adult gastroscope with a distal cap is commonly used for duodenal EMRs. Based on the location, however, side-viewing duodenoscopes or pediatric colonoscopes may be used. To prepare for EMR, a submucosal injection is performed for an adequate lift. The polyp is then resected via stiff monofilament snares and subsequently closed with hemostatic clips if feasible. The ampullectomy technique differs slightly from duodenal EMRs and carries the additional risk of pancreatitis. Submucosal injection in the ampulla may not lift well; thus, its utility is debatable. Biliary sphincterotomy should be performed, and based on endoscopist preference, the pancreatic duct (PD) guidewire can be left during resection to maintain access. After resection, a PD stent is placed to minimize pancreatitis risk. Results: The video shows the aforementioned duodenal EMR techniques. Two clips of ampullectomy are also shown in the video. Conclusions: A few common techniques used to perform duodenal EMR and ampullectomy are highlighted in the video. It is important to understand and manage adverse events associated with these procedures and to have established surveillance plans.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.