Trial reportUltrasound in medicine & biology2023
Assessing the Effect of Augmented Reality on Procedural Outcomes During Ultrasound-Guided Vascular Access.
Trial report in Ultrasound in medicine & biology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07208071 (Application of Augmented Reality for Point of Care Ultrasound-Guided Procedures), which is not on this map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Application of Augmented Reality for Point of Care Ultrasound-Guided Procedures
Who cites it
13 citing papers in PubMed, 24 citations in OpenAlex.
- Augmented Reality Ultrasound-Guided Vascular Access via Apple Vision Pro.Journal of the Society for Cardiovascular Angiography & Interventions · 2026Article
- Augmented reality for ultrasound-guided venipuncture: a pilot study on a simulated vascular access model.Journal of clinical monitoring and computing · 2026Article
- Augmented-reality enhanced ultrasound guidance: a sterile, hands-free approach using commercial augmented reality headsets.Radiological physics and technology · 2026Article
- Using head-mounted augmented and virtual reality devices for anaesthesia education: a scoping review.BJA open · 2026Review
- Three-Dimensional Reconstruction and Navigation Systems in Endoscopic Ultrasound Procedures: A Comprehensive Review.Diagnostics (Basel, Switzerland) · 2026Review
- Assessment of cybersickness induced by augmented reality ultrasound procedures using head-mounted display.Frontiers in digital health · 2026Article
- The digital evolution of surgical planning: a systematic review of immersive and interactive technologies.Frontiers in surgery · 2026Review
- Future Designs of Clinical Trials in Nephrology: Integrating Methodological Innovation and Computational Power.Sensors (Basel, Switzerland) · 2025Review
- Virtual Ultrasound-Guided Central Vascular Access Using Apple Vision Pro: An Evaluation and Proof of Concept.Cureus · 2025Article
- Effectiveness of Virtual and Augmented Reality for Emergency Healthcare Training: A Randomized Controlled Trial.Healthcare (Basel, Switzerland) · 2025Article
- Augmented reality for point-of-care ultrasound-guided vascular access in pediatric patients using Microsoft HoloLens 2: a preliminary evaluation.Journal of medical imaging (Bellingham, Wash.) · 2024Article
- U-Net and Its Variants Based Automatic Tracking of Radial Artery in Ultrasonic Short-Axis Views: A Pilot Study.Diagnostics (Basel, Switzerland) · 2024Article
- Evolutionary trends and innovations in cardiovascular intervention.Frontiers in medical technology · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 4 institutions in 1 country.
Funding
Abstract
objectiveAugmented reality devices are increasingly accepted in health care, though most applications involve education and pre-operative planning. A novel augmented reality ultrasound application, HoloUS, was developed for the Microsoft HoloLens 2 to project real-time ultrasound images directly into the user's field of view. In this work, we assessed the effect of using HoloUS on vascular access procedural outcomes.
methodsA single-center user study was completed with participants with (N = 22) and without (N = 12) experience performing ultrasound-guided vascular access. Users completed a venipuncture and aspiration task a total of four times: three times on study day 1, and once on study day 2 between 2 and 4 weeks later. Users were randomized to use conventional ultrasound during either their first or second task and the HoloUS application at all other times. Task completion time, numbers of needle re-directions, head adjustments and needle visualization rates were recorded.
resultsFor expert users, task completion time was significantly faster using HoloUS (11.5 s, interquartile range [IQR] = 6.5-23.5 s vs. 18.5 s, IQR = 11.0-36.5 s; p = 0.04). The number of head adjustments was significantly lower using the HoloUS app (1.0, IQR = 0.0-1.0 vs. 3.0, IQR = 1.0-5.0; p < 0.0001). No significant differences were identified in other measured outcomes.
conclusionThis is the first investigation of augmented reality-based ultrasound-guided vascular access using the second-generation HoloLens. It demonstrates equivalent procedural efficiency and accuracy, with favorable usability, ergonomics and user independence when compared with traditional ultrasound techniques.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.