Evidence map›Paper›PMID 37571744›Full record

ArticleSensors (Basel, Switzerland)2023

Fabrication of Micro-Cantilever Sensor Based on Clay Minerals for Humidity Detection.

Yiting Xu, Song Liu, Junfeng Zhang, Songyang Chai, Jianjun Li, Changguo Xue, Shangquan Wu

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yiting XuSchool of Materials Science and Engineering, Anhui University of Science and Technology, Huainan 232001, China.ORCID 0009-0005-0890-5626
Song LiuSchool of Materials Science and Engineering, Anhui University of Science and Technology, Huainan 232001, China.ORCID 0000-0003-4247-1778
Junfeng ZhangSchool of Materials Science and Engineering, Anhui University of Science and Technology, Huainan 232001, China.ORCID 0009-0002-5915-9094
Songyang ChaiSchool of Materials Science and Engineering, Anhui University of Science and Technology, Huainan 232001, China.ORCID 0009-0008-0557-4579
Jianjun LiSchool of Materials Science and Engineering, Anhui University of Science and Technology, Huainan 232001, China.ORCID 0000-0001-6562-2466
Changguo XueSchool of Materials Science and Engineering, Anhui University of Science and Technology, Huainan 232001, China.ORCID 0000-0001-9671-5542
Shangquan WuCAS Key Laboratory of Mechanical Behavior and Design of Materials, University of Science and Technology of China, Hefei 230026, China.

Funding

Key Research and Development Program Projects in Anhui Province Grant Nos. 202004h07020026National Natural Science Foundation of China Grant Nos.12172002
6 · The paper itself

Abstract

In this paper, novel humidity sensors based on montmorillonite, kaolinite, and composite films coated on micro-cantilevers were prepared to measure the relative humidity (RH) values by the deflection of a micro-cantilever (MC) at room temperature. The humidity-sensing properties, such as response and recovery, sensitivity, repeatability, humidity hysteresis, and long-term stability, were investigated in the range of working humidity (10-80% RH). The humidity response in the close humidity range of 10% RH to 80% RH revealed a linear increase in water absorption of montmorillonite, kaolinite, and montmorillonite/kaolinite mixed dispersant (1:1) as a function of RH with linear correlation factors between the humidity change and deflection estimated to be 0.994, 0.991, and 0.946, respectively. Montmorillonite's sensitivity was better than kaolinite's, with the mixed-clay mineral film's response falling somewhere in between. This research provides a feasible and effective approach to constructing high-performance MC humidity sensors that can be operated at room temperature based on clay minerals.