Evidence map›Paper›PMID 37571530›Full record

ArticleSensors (Basel, Switzerland)2023

Foot Sole Contact Forces vs. Ground Contact Forces to Obtain Foot Joint Moments for In-Shoe Gait-A Preliminary Study.

Joaquín L Sancho-Bru, Enrique Sanchis-Sales, Pablo J Rodríguez-Cervantes, Carles Vergés-Salas

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 53% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

Joaquín L Sancho-BruDepartment of Mechanical Engineering and Construction, Universitat Jaume I, 12071 Castellón de la Plana, Spain.ORCID 0000-0001-8486-5113
Enrique Sanchis-SalesDepartmental Section of Podiatry, Nursing Department, Universitat de València, 46010 Valencia, Spain.
Pablo J Rodríguez-CervantesDepartment of Mechanical Engineering and Construction, Universitat Jaume I, 12071 Castellón de la Plana, Spain.ORCID 0000-0002-0627-9036
Carles Vergés-SalasDepartmental Section of Podiatry, Department of Clinical Sciences, Faculty of Medicine and Health Sciences, Universitat de Barcelona, 08907 L'Hospitalet de Llobregat, Spain.
Universitat Jaume I · ESUniversitat de Barcelona · ESUniversitat de València · ES

Funding

Jaume I University UJI-B2021-59
6 · The paper itself

Abstract

In-shoe models are required to extend the clinical application of current multisegment kinetic models of the bare foot to study the effect of foot orthoses. Work to date has only addressed marker placement for reliable kinematic analyses. The purpose of this study is to address the difficulties of recording contact forces with available sensors. Ten participants walked 5 times wearing two different types of footwear by stepping on a pressure platform (ground contact forces) while wearing in-shoe pressure sensors (foot sole contact forces). Pressure data were segmented by considering contact cells' anteroposterior location, and were used to compute 3D moments at foot joints. The mean values and 95% confidence intervals were plotted for each device per shoe condition. The peak values and times of forces and moments were computed per participant and trial under each condition, and were compared using mixed-effect tests. Test-retest reliability was analyzed by means of intraclass correlation coefficients. The curve profiles from both devices were similar, with higher joint moments for the instrumented insoles at the metatarsophalangeal joint (~26%), which were lower at the ankle (~8%) and midtarsal (~15%) joints, although the differences were nonsignificant. Not considering frictional forces resulted in ~20% lower peaks at the ankle moments compared to previous studies, which employed force plates. The device affected both shoe conditions in the same way, which suggests the interchangeability of measuring joint moments with one or the other device. This hypothesis was reinforced by the intraclass correlation coefficients, which were higher for the peak values, although only moderate-to-good. In short, both considered alternatives have drawbacks. Only the instrumented in-soles provided direct information about foot contact forces, but it was incomplete (evidenced by the difference in ankle moments between devices). However, recording ground reaction forces offers the advantage of enabling the consideration of contact friction forces (using force plates in series, or combining a pressure platform and a force plate to estimate friction forces and torque), which are less invasive than instrumented insoles (which may affect subjects' gait).

Indexed as

FootShoesBiomechanical PhenomenaFoot JointsGaitHumansReproducibility of Resultsforce platein-shoe modelinstrumented insolesmultisegment kinetic foot modelpressure platform

Identifiers

PMID37571530
PMCPMC10422389
OpenAlexW4385349587

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.