Evidence map›Paper›PMID 37571465›Full record

ArticleSensors (Basel, Switzerland)2023

A Real-Time Evaluation Algorithm for Noncontact Heart Rate Variability Monitoring.

Xiangyu Han, Qian Zhai, Ning Zhang, Xiufeng Zhang, Long He, Min Pan, Bin Zhang, Tao Liu

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
2.0field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 18 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 3 countries.

Xiangyu HanState Key Laboratory of Fluid Power and Mechatronic Systems, School of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China.ORCID 0000-0003-0412-9859
Qian ZhaiState Key Laboratory of Fluid Power and Mechatronic Systems, School of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China.ORCID 0000-0001-8426-1205
Ning ZhangNational Research Center for Rehabilitation Technical Aids, Beijing 100176, China.
Xiufeng ZhangNational Research Center for Rehabilitation Technical Aids, Beijing 100176, China.
Long HeZhiyuan Research Institute, Hangzhou 310024, China.
Min PanDepartment of Mechanical Engineering, University of Bath, Bath BA2 7AY, UK.ORCID 0000-0002-2901-3388
Bin ZhangDepartment of Electrical Engineering, University of South Carolina, Columbia, SC 29208, USA.ORCID 0000-0002-4879-0211
Tao LiuState Key Laboratory of Fluid Power and Mechatronic Systems, School of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China.ORCID 0000-0002-2797-0264
Zhejiang University · CNNational Research Center for Rehabilitation Technical Aids · CNUniversity of Bath · GBUniversity of South Carolina · US

Funding

Key Research and Development Program of Zhejiang 2021C03051Key Research and Development Program of Zhejiang 2022C03103National Natural Science Foundation of China 52175033National Natural Science Foundation of China U1913601National Natural Science Foundation of China U21A20120Zhejiang Provincial Natural Science Foundation of China LZ20E050002
6 · The paper itself

Abstract

Noncontact vital sign monitoring based on radar has attracted great interest in many fields. Heart Rate Variability (HRV), which measures the fluctuation of heartbeat intervals, has been considered as an important indicator for general health evaluation. This paper proposes a new algorithm for HRV monitoring in which frequency-modulated continuous-wave (FMCW) radar is used to separate echo signals from different distances, and the beamforming technique is adopted to improve signal quality. After the phase reflecting the chest wall motion is demodulated, the acceleration is calculated to enhance the heartbeat and suppress the impact of respiration. The time interval of each heartbeat is estimated based on the smoothed acceleration waveform. Finally, a joint optimization algorithm was developed and is used to precisely segment the acceleration signal for analyzing HRV. Experimental results from 10 participants show the potential of the proposed algorithm for obtaining a noncontact HRV estimation with high accuracy. The proposed algorithm can measure the interbeat interval (IBI) with a root mean square error (RMSE) of 14.9 ms and accurately estimate HRV parameters with an RMSE of 3.24 ms for MEAN (the average value of the IBI), 4.91 ms for the standard deviation of normal to normal (SDNN), and 9.10 ms for the root mean square of successive differences (RMSSD). These results demonstrate the effectiveness and feasibility of the proposed method in emotion recognition, sleep monitoring, and heart disease diagnosis.

Indexed as

Heart Rate DeterminationRespirationAlgorithmsHeart RateHumansMonitoring, PhysiologicSignal Processing, Computer-AssistedalgorithmFMCW radarheartbeatHRVnoncontact monitoringvital sign monitoringwireless signal

Identifiers

PMID37571465
PMCPMC10422594
OpenAlexW4385363744

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked