Evidence map›Paper›PMID 37566300›Full record

ArticleInternational journal of computer assisted radiology and surgery2023

Novel and inexpensive gamma radiation sensor: initial concept and design.

Joanna Sorysz, Katarzyna Heryan, Gabriele Krombach, Michael Friebe, Peter P Pott

Open access · hybridAbstract read
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
1.1field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 3 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 5 institutions in 2 countries.

Joanna SoryszDepartment of Biocybernetics and Biomedical Engineering, AGH University of Science and Technology, Kraków, Poland. jsorysz@gmail.com.ORCID http://orcid.org/0000-0002-9213-5468
Katarzyna HeryanDepartment of Biocybernetics and Biomedical Engineering, AGH University of Science and Technology, Kraków, Poland.
Gabriele KrombachDiagnostic and Interventional Radiology and Pediatric Radiology, Giessen University Hospital, Giessen, Germany.
Michael FriebeDepartment of Biocybernetics and Biomedical Engineering, AGH University of Science and Technology, Kraków, Poland.
Peter P PottInstitute of Medical Device Technology, University of Stuttgart, Stuttgart, Germany.
AGH University of Krakow · PLFOM University of Applied Sciences for Economics and Management · DEInstitute of Biocybernetics and Biomedical Engineering · PLUniversitätsklinikum Gießen und Marburg · DEUniversity of Stuttgart · DE

Funding

Narodowym Centrum Nauki 504923173 / KR 2241/6- 1
6 · The paper itself

Abstract

purposeEarly detection of tumors and their spread, particularly in lymph node illnesses, is critical for a full recovery. However, it is currently difficult due to a lack of imaging or detection devices that provide the necessary spatial depth and location information. Consequently, it would be beneficial to have a simple and cost-effective sensor device to determine the 3D position of, e.g., a lymph node in the patient's coordinate system.

methodsIn this work, we present a concept and design for a novel semiconductor-based 3D detection system that uses inexpensive off-the-shelf components to measure gamma activity. A simple Arduino-type microcontroller calculates the 3D position of the probe based on the number of the measured pulse, the spatial sensitivity characteristics, and the known geometry of the device.

resultsThe system was set up from four photodiodes (Osram BPW34), a transistor-based pre-amplifier, and a two-stage operational amplifier as the main stage. Doing so, a signal sufficient to be read by the microcontroller could be produced. The performed calculations proved that for a system consisting of at least four photodiodes, it is possible to determine precise location of a gamma radiation source.

conclusionsAfter successful first experiments with a single diode, the optimal spatial arrangement of the diodes as well as their orientation will be determined to achieve a compact, cost effective yet fast, and accurate sensor device for every-day clinical application.

Indexed as

Gamma RaysImaging, Three-DimensionalEquipment DesignHumansSemiconductorsGamma radiationLymph nodes tumourMedical guidancePhotodiodesTumour detection

Identifiers

PMID37566300
PMCPMC10589134
OpenAlexW4385751310

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.