Evidence map›Paper›PMID 37562441›Full record

ArticleKorean journal of ophthalmology : KJO2023

Effect and Safety of Pressure Sensor-equipped Handpiece in Phacoemulsification System.

Jin Yeong Kim, Harin Kim, Ikhyun Jun, Tae-Im Kim, Kyoung Yul Seo

Open access · goldAbstract read
In one paragraph

Article in Korean journal of ophthalmology : KJO, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
3.1field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 11 citations in OpenAlex.

  1. Trial
  2. Article
  3. Observational
  4. Review
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Jin Yeong KimInstitute of Vision Research, Department of Ophthalmology, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.
Harin KimInstitute of Vision Research, Department of Ophthalmology, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.
Ikhyun JunInstitute of Vision Research, Department of Ophthalmology, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.
Tae-Im KimInstitute of Vision Research, Department of Ophthalmology, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.
Kyoung Yul SeoInstitute of Vision Research, Department of Ophthalmology, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.
Severance Hospital · KRYonsei University · KR

Funding

Korean Fund for Regenerative Medicine 22C0615L1Ministry of Health and WelfareMinistry of Science and ICTNational Research Foundation of Korea 2021R1I1A1A01047951Yonsei University College of Medicine 2022-32-0071
6 · The paper itself

Abstract

purposeTo evaluate the effect of the Active Sentry handpiece of the Centurion Vision System compared to the Centurion Ozil handpiece for phacoemulsification in cataract surgery.

methodsA retrospective study was conducted on 281 patients (449 eyes) who underwent cataract surgery between August 2020 and June 2021. Preoperative measurements, intraoperative parameters, complication rate, and postoperative outcomes were compared between the Active Sentry handpiece and the Centurion Ozil handpiece groups. Additionally, the parameters were compared in different cataract severity groups and multiple predictive factors for the number of active surge mitigation (ASM) actuations were assessed with the Active Sentry handpiece.

resultsThere were 198 eyes in the Active Sentry group and 251 eyes in the Centurion Ozil group. There were no statistically significant differences between the two groups, as the cumulative dissipated energy in the Active Sentry and Centurion Ozil groups were 8.32 ± 7.74 and 7.87 ± 9.25 μJ, respectively (p = 0.576). Total surgery time, ultrasound usage time, aspiration time, amount of fluid aspirated, postoperative corrected distant visual acuity, and postoperative decrease in corneal endothelial cell density were comparable between the two groups. The significant contributors to the number of ASM actuations were age, preoperative corrected distant visual acuity, axial length, and total ultrasound time.

conclusionsThere was no clear advantage of the Active Sentry handpiece compared to the Centurion Ozil handpiece. ASM actuation increases with age, poor visual acuity before surgery, short axial length, and prolonged ultrasound usage time. It is expected that in more severe and high-risk cataract surgery, the Active Sentry handpiece functions more effectively, possibly affecting the safety and prognosis.

Indexed as

Intraocular PressurePhacoemulsificationVisual AcuityAgedAged, 80 and overEquipment DesignFemaleFollow-Up StudiesHumansMaleMiddle AgedRetrospective StudiesActive fluidicsActive sentry handpieceCataractPhacoemulsificationRetrospective study

Identifiers

PMID37562441
PMCPMC10587456
OpenAlexW4385721228

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.