Evidence map›Paper›PMID 37561749›Full record

ArticlePloS one2023

Two-photon microscopy for microrobotics: Visualization of micro-agents below fixed tissue.

Juan J Huaroto, Luigi Capuano, Mert Kaya, Ihar Hlukhau, Franck Assayag, Sumit Mohanty, Gert-Willem Römer, Sarthak Misra

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 47% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Juan J HuarotoSurgical Robotics Laboratory, Department of Biomechanical Engineering, University of Twente, Enschede, The Netherlands.ORCID 0000-0002-7154-7893
Luigi CapuanoSurgical Robotics Laboratory, Department of Biomechanical Engineering, University of Twente, Enschede, The Netherlands.
Mert KayaSurgical Robotics Laboratory, Department of Biomechanical Engineering, University of Twente, Enschede, The Netherlands.
Ihar HlukhauSurgical Robotics Laboratory, Department of Biomechanical Engineering, University of Twente, Enschede, The Netherlands.
Franck AssayagAnimal Facility, Technical Medical Centre (TechMed Centre) Infrastructure, Faculty of Science and Technology, University of Twente, Enschede, The Netherlands.
Sumit MohantySurgical Robotics Laboratory, Department of Biomechanical Engineering, University of Twente, Enschede, The Netherlands.ORCID 0000-0002-7423-3611
Gert-Willem RömerChair of Laser Processing, Department of Mechanics of Solids, Surfaces & Systems (MS3), Faculty of Engineering Technology, University of Twente, Enschede, The Netherlands.ORCID 0000-0003-2359-7471
Sarthak MisraSurgical Robotics Laboratory, Department of Biomechanical Engineering, University of Twente, Enschede, The Netherlands.
University of Twente · NLUniversity Medical Center Groningen · NLInstitute for Atomic and Molecular Physics · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Optical microscopy is frequently used to visualize microrobotic agents (i.e., micro-agents) and physical surroundings with a relatively high spatio-temporal resolution. However, the limited penetration depth of optical microscopy techniques used in microrobotics (in the order of 100 μm) reduces the capability of visualizing micro-agents below biological tissue. Two-photon microscopy is a technique that exploits the principle of two-photon absorption, permitting live tissue imaging with sub-micron resolution and optical penetration depths (over 500 μm). The two-photon absorption principle has been widely applied to fabricate sub-millimeter scale components via direct laser writing (DLW). Yet, its use as an imaging tool for microrobotics remains unexplored in the state-of-the-art. This study introduces and reports on two-photon microscopy as an alternative technique for visualizing micro-agents below biological tissue. In order to validate two-photon image acquisition for microrobotics, two-type micro-agents are fabricated and employed: (1) electrospun fibers stained with an exogenous fluorophore and (2) bio-inspired structure printed with autofluorescent resin via DLW. The experiments are devised and conducted to obtain three-dimensional reconstructions of both micro-agents, perform a qualitative study of laser-tissue interaction, and visualize micro-agents along with tissue using second-harmonic generation. We experimentally demonstrate two-photon microscopy of micro-agents below formalin-fixed tissue with a maximum penetration depth of 800 μm and continuous imaging of magnetic electrospun fibers with one frame per second acquisition rate (in a field of view of 135 × 135 μm2). Our results show that two-photon microscopy can be an alternative imaging technique for microrobotics by enabling visualization of micro-agents under in vitro and ex ovo conditions. Furthermore, bridging the gap between two-photon microscopy and the microrobotics field has the potential to facilitate in vivo visualization of micro-agents.

Indexed as

Imaging, Three-DimensionalMicroscopy, Fluorescence, MultiphotonFluorescent DyesPhotonsFluorescent Dyes

Identifiers

PMID37561749
PMCPMC10414647
OpenAlexW4385727604

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.