Evidence map›Paper›PMID 37554650›Full record

ArticleFrontiers in neuroimaging2023

DSC MRI in the human brain using deoxyhemoglobin and gadolinium-Simulations and validations at 3T.

Jacob Benjamin Schulman, Ece Su Sayin, Angelica Manalac, Julien Poublanc, Olivia Sobczyk, James Duffin, Joseph A Fisher, David Mikulis, Kâmil Uludağ

Abstract read
In one paragraph

Article in Frontiers in neuroimaging, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Blood-brain barrier breakdown in brain ischemia: Insights from MRI perfusion imaging.Neurotherapeutics : the journal of the American Society for Experimental NeuroTherapeutics · 2025
    Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Sinusoidal COFrontiers in physiology · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Jacob Benjamin SchulmanDepartment of Medical Biophysics, University of Toronto, Toronto, ON, Canada.
Ece Su SayinDepartment of Physiology, University of Toronto, Toronto, ON, Canada.
Angelica ManalacDepartment of Medical Biophysics, University of Toronto, Toronto, ON, Canada.
Julien PoublancJoint Department of Medical Imaging and the Functional Neuroimaging Lab, University Health Network, Toronto, ON, Canada.
Olivia SobczykJoint Department of Medical Imaging and the Functional Neuroimaging Lab, University Health Network, Toronto, ON, Canada.
James DuffinDepartment of Physiology, University of Toronto, Toronto, ON, Canada.
Joseph A FisherDepartment of Physiology, University of Toronto, Toronto, ON, Canada.
David MikulisKrembil Brain Institute, University Health Network, Toronto, ON, Canada.
Kâmil UludağDepartment of Medical Biophysics, University of Toronto, Toronto, ON, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Dynamic susceptibility contrast (DSC) MRI allows clinicians to determine perfusion parameters in the brain, such as cerebral blood flow, cerebral blood volume, and mean transit time. To enable quantification, susceptibility changes can be induced using gadolinium (Gd) or deoxyhemoglobin (dOHb), the latter just recently introduced as a contrast agent in DSC. Previous investigations found that experimental parameters and analysis choices, such as the susceptibility amplitude and partial volume, affect perfusion quantification. However, the accuracy and precision of DSC MRI has not been systematically investigated, particularly in the lower susceptibility range. Methods: In this study, we compared perfusion values determined using Gd with values determined using a contrast agent with a lower susceptibility-dOHb-under different physiological conditions, such as varying the baseline blood oxygenation and/or magnitude of hypoxic bolus, by utilizing numerical simulations and conducting experiments on healthy subjects at 3T. The simulation framework we developed for DSC incorporates MRI signal contributions from intravascular and extravascular proton spins in arterial, venous, and cerebral tissue voxels. This framework allowed us to model the MRI signal in response to both Gd and dOHb. Results and discussion: We found, both in the experimental results and simulations, that a reduced intravascular volume of the selected arterial voxel, reduced baseline oxygen saturation, greater susceptibility of applied contrast agent (Gd vs. dOHb), and/or larger magnitude of applied hypoxic bolus reduces the overestimation and increases precision of cerebral blood volume and flow. As well, we found that normalizing tissue to venous rather than arterial signal increases the accuracy of perfusion quantification across experimental paradigms. Furthermore, we found that shortening the bolus duration increases the accuracy and reduces the calculated values of mean transit time. In summary, we experimentally uncovered an array of perfusion quantification dependencies, which agreed with the simulation framework predictions, using a wider range of susceptibility values than previously investigated. We argue for caution when comparing absolute and relative perfusion values within and across subjects obtained from a standard DSC MRI analysis, particularly when employing different experimental paradigms and contrast agents.

Indexed as

deoxyhemoglobinDSCgadoliniumperfusionsimulations

Identifiers

PMID37554650
PMCPMC10406263

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.