Evidence map›Paper›PMID 37553114›Full record

ArticleArchivos de cardiologia de Mexico2023

Use of subcutaneous cardioverter-defibrillator. First cases reported from National Institute of Cardiology Ignacio Chávez-Mexico.

Manlio F Márquez-Murillo, Carlos A Chávez-Gutiérrez, Sergio Díaz-Tostado, Gabriela Bustillos-García, Jorge Gómez-Flores, Santiago Nava-Townsend

Abstract read
In one paragraph

Article in Archivos de cardiologia de Mexico, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Manlio F Márquez-MurilloDepartamento de Investigación Clínica.
Carlos A Chávez-GutiérrezDepartamento de Electrofisiología pediátrica.
Sergio Díaz-TostadoDepartamento de Electrofisiología pediátrica.
Gabriela Bustillos-GarcíaDepartamento de Electrofisiología pediátrica.
Jorge Gómez-FloresDepartamento de Electrofisiología. Instituto Nacional de Cardiología, Ciudad de México, México.
Santiago Nava-TownsendDepartamento de Electrofisiología. Instituto Nacional de Cardiología, Ciudad de México, México.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe transvenous implantable cardioverter defibrillator (ICD) is the treatment of choice for the prevention of sudden cardiac death (SCD). Its use could be restricted when device-related infections occurs or in the pediatric population. In the later, an ICD represents a challenge, due to the minimal dimensions of the venous system in children, the length of the electrodes, the size of the generator, as well as the anatomical complexity in cases with associated congenital heart disease.

objectiveThis article presents the first Mexican patients with a subcutaneous ICD (SC-ICD) implant as a therapy for the prevention of SCD.

methodsThe first four cases were implanted at the Ignacio Chávez National Institute of Cardiology with a SC-ICD (Emblem, Boston Scientific, USA), three of them were pediatric patients, including the first implant of this type of device in a pediatric patient in Latin America. The 3-incision and 2-incision techniques were used under general anesthesia.

resultsA successful implantation was obtained with the 3-incision technique in the first 2 cases and the last 2 with the 2-incision technique. Proper functioning of the device was corroborated in the operating room with proof of appropriate therapy (65 J) for ventricular fibrillation induced with 50 Hz stimulation. No immediate complications were observed. One patient had appropriate shocks two months after the implant. During follow-up, one child developed skin erosion at the level of the curve of the electrode on the sternum, with no signs of infection. In the operating room, the damaged skin was resected, the barrel and the fixation silk were removed, surgical lavage was performed, and the skin was closed again, thus avoiding removal of the system.

conclusionsThe SC-ICD is an alternative therapy to the transvenous ICD. It can be considered first choice in subjects who do not require ventricular pacing, including pediatric patients. Skin complications can occur but do not pose a threat as venous complications of conventional ICDs.

Indexed as

CardiologyDefibrillators, ImplantableChildDeath, Sudden, CardiacElectric CountershockHumansMexicoTreatment OutcomeDesfibrilador subcutáneoHypertrophic cardiomyopathyLong QT syndromeMexicoMéxicoMiocardiopatía hipertróficaMuerte súbita cardiacaSíndrome de QT largoSubcutaneous cardioverter-defibrillatorSudden cardiac death

Identifiers

PMID37553114
PMCPMC10406479

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.