Evidence map›Paper›PMID 37551341›Full record

ArticleJournal of multidisciplinary healthcare2023

Satisfaction of Health Professionals Regarding the Short Binasal Prong Used as a Non-Invasive Ventilation Interface in Neonatology.

Débora de Fátima Camillo Ribeiro, Paula Karina Hembecker, Adriane Muller Nakato, Beatriz Luci Fernandes, Percy Nohama

Abstract read
In one paragraph

Article in Journal of multidisciplinary healthcare, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Débora de Fátima Camillo RibeiroNeonatal Services, Waldemar Monastier Hospital, Campo Largo, Paraná, Brazil.ORCID 0000-0003-4482-8574
Paula Karina HembeckerGraduate Program on Health Technology, Pontifícia Universidade Católica Do Paraná, Curitiba, Paraná, Brazil.ORCID 0000-0002-6998-8518
Adriane Muller NakatoGraduate Program on Health Technology, Pontifícia Universidade Católica Do Paraná, Curitiba, Paraná, Brazil.ORCID 0000-0003-0781-988X
Beatriz Luci FernandesGraduate Program on Health Technology, Pontifícia Universidade Católica Do Paraná, Curitiba, Paraná, Brazil.ORCID 0000-0003-1751-7930
Percy NohamaGraduate Program on Health Technology, Pontifícia Universidade Católica Do Paraná, Curitiba, Paraná, Brazil.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To evaluate the health professionals' satisfaction regarding the short binasal prong used in Neonatal Intensive Care Units (NICU), evaluate the difficulties related to its use, and present possible improvements in the design of this device. Patients and Methods: Observational, cross-sectional study with prospective data collection carried out in the NICU of a public hospital in southern Brazil. This research was presented into two stages. In the first stage, the Quebec User Evaluation of Satisfaction with Assistive Technology was applied with 90 health professionals to evaluate the satisfaction regarding the short binasal prong. In the second stage, the health professional's experiences and difficulties in using the binasal prongs in 14 newborns (NBs) that required non-invasive ventilation was collected. The short binasal prongs used was the Fanem Results: The mean score of the health professionals' satisfaction with short binasal prongs was 3.8 ± 0.6. Ease of adjustment (3.27) and dimensions (3.62) variables had the worst scores. The main difficulties pointed out by health professionals were: circuit disconnection (57.1%), the size of the prong did not correspond to NBs' anatomical characteristics (35.7%), air leakage (21.4%), and difficulty in fixing and positioning the prong in the NB (14.28%). The improvements suggested were: appropriate prong sizes based on the anatomical characteristics of the NBs; adjustable distance between insertion and base catheters; manufactured with malleable material, however not easily foldable; curved and adjustable insertion catheters and functional system of tracheas' connection. Conclusion: The dissatisfaction of health professionals with the dimensions and prongs adjustments and the difficulties faced in clinical practice indicate the need for improvements in these interfaces. The recommendations presented in this study may contribute to optimizing the design of the binasal prong in the future.

Indexed as

assistive technologyneonatal intensive carenon-invasive ventilationsurveys and questionnaires

Identifiers

PMID37551341
PMCPMC10404407

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.