Investigation of the factors influencing spinal manipulative therapy force transmission through the thorax: a cadaveric study.

Jérémie Mikhail, Martha Funabashi, Stéphane Sobczak, Martin Descarreaux, Isabelle Pagé

Abstract read
In one paragraph

Article in Chiropractic & manual therapies, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Spinal manipulation/mobilization: past, present, future.Chiropractic & manual therapies · 2025
    Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jérémie MikhailDepartment of Chiropractic, Université du Québec à Trois-Rivières, 3351 Boul. des Forges, Trois-Rivières, QC, G8Z 4M3, Canada.
Martha FunabashiDepartment of Chiropractic, Université du Québec à Trois-Rivières, 3351 Boul. des Forges, Trois-Rivières, QC, G8Z 4M3, Canada.
Stéphane SobczakResearch Group on Neuromusculoskeletal Disorders, Université du Québec à Trois-Rivières, 3351 Boul. des Forges, Trois-Rivières, QC, G8Z 4M3, Canada.
Martin DescarreauxResearch Group on Neuromusculoskeletal Disorders, Université du Québec à Trois-Rivières, 3351 Boul. des Forges, Trois-Rivières, QC, G8Z 4M3, Canada.
Isabelle PagéDepartment of Chiropractic, Université du Québec à Trois-Rivières, 3351 Boul. des Forges, Trois-Rivières, QC, G8Z 4M3, Canada. isabelle.page1@uqtr.ca.ORCID http://orcid.org/0000-0002-7175-0402

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSpinal manipulative therapy (SMT) clinical effects are believed to be linked to its force-time profile characteristics. Previous studies have revealed that the force measured at the patient-table interface is most commonly greater than the one applied at the clinician-patient interface. The factors explaining this force amplification remains unclear.

objectiveTo determine the difference between the force applied to a cadaveric specimen's thoracic spine and the resulting force measured by a force-sensing table, as well as to evaluate the relationship between this difference and both the SMT force-time characteristics and the specimens' characteristics.

methodsTwenty-five SMTs with different force-time profiles were delivered by an apparatus at the T7 vertebra of nine human cadaveric specimens lying prone on a treatment table equipped with a force plate. The difference between the force applied by the apparatus and the resulting force measured by the force plate was calculated in absolute force (F

resultsSixty percent of the trials showed lower force measured at the force plate than the one applied at T7. F

conclusionDifference in force between the clinician-patient and the patient-table interfaces is influenced by SMT force-time characteristics and by thoracic thickness. How these differences in force are associated with vertebral displacements remains unclear. Although further studies are needed, clinicians should consider thorax thickness as a possible modulator of forces being transmitted through it during prone SMT procedures.

Indexed as

Manipulation, SpinalBiomechanical PhenomenaCadaverHumansThoracic VertebraeThoraxCadaveric studyClinician-patient interfaceForce–time characteristicsKinematicKineticPatient-table interfaceSpinal manipulationSpinal mobilization

Identifiers

PMID37550682
PMCPMC10405484

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.