Evidence map›Paper›PMID 37550653›Full record

ArticleBMC musculoskeletal disorders2023

3D simulation of percutaneous sustentaculum tali screw insertion in calcaneal fractures.

Xian Li, Xiao-Ke Wang, Lian-Kui Yu, Chao Zhang, Ming-Ming Zhao, Jun Yan, Li-Ren Han

Open access · goldAbstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.2field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Xian Li *School of Clinical Medicine, Weifang Medical University, Weifang, China.
Xiao-Ke WangSchool of Clinical Medicine, Weifang Medical University, Weifang, China.
Lian-Kui Yu *Department of Orthopaedic Surgery, Liaocheng People's Hospital, Liaocheng, China.
Chao ZhangDepartment of Orthopaedic Surgery, Liaocheng People's Hospital, Liaocheng, China.
Ming-Ming ZhaoDepartment of Orthopaedic Surgery, Liaocheng People's Hospital, Liaocheng, China.
Jun YanDepartment of Orthopaedic Surgery, Liaocheng People's Hospital, Liaocheng, China. awpkaka@126.com.
Li-Ren HanDepartment of Orthopaedic Surgery, Liaocheng People's Hospital, Liaocheng, China. fuleco@126.com.
Liaocheng People's Hospital · CNWeifang Medical University · CN

Funding

Natural Science Foundation of ShanDong province No. ZR202102280280
6 · The paper itself

Abstract

backgroundIn calcaneal fractures, the percutaneous screw fixation (PSF) is currently considered to be the better choice, but it is difficult to accurately place the screw into the sustentaculum tali (ST) during the operation. In this study, the ideal entry point, angle, diameter and length of the screw were calculated by simulating the operation process.

methodsWe retrospectively collected the calcaneus computed tomography (CT) scans of 180 adults, DICOM-formatted CT-scan images of each patient were imported into Mimics software to establish calcaneus model. Virtual screws were placed on the lateral of the posterior talar articular surface (PTAS), the lateral edge of the anterior process of calcaneus (APC), and the calcaneal tuberosity, respectively, the trajectory and size of the screws were calculated.

resultsThe mean maximum diameter of the PTAS screw was 42.20 ± 3.71 mm. The vertical distance between the midpoint of the APC optimal screw trajectory and the lowest point of the tarsal sinus was 10.67 ± 1.84 mm, and the distance between the midpoint of the APC optimal screw trajectory and the calcaneocuboid joint was 5 mm ~ 19.81 ± 2.08 mm. The mean maximum lengths of APC screws was 44.69 ± 4.81 mm, and the Angle between the screw and the coronal plane of the calcaneus from proximal to distal was 4.72°±2.15° to 20.52°±3.77°. The optimal point of the maximum diameter of the calcaneal tuberosity screw was located at the lateral border of the achilles tendon endpoint. The mean maximum diameters of calcaneal tuberosity screws was 4.46 ± 0.85 mm, the mean maximum lengths of screws was 65.31 ± 4.76 mm. We found gender-dependent differences for the mean maximum diameter and the maximum length of the three screws.

conclusionsThe study provides effective positioning for percutaneous screw fixation of calcaneal fractures. For safer and more efficient screw placement, we suggest individualised preoperative 3D reconstruction simulations. Further biomechanical studies are needed to verify the function of the screw.

Indexed as

Ankle InjuriesCalcaneusFractures, BoneAdultBone ScrewsFracture Fixation, InternalHumansRetrospective StudiesCalcaneal fractureDigital measurementPercutaneous screw fixationSustentaculum tali

Identifiers

PMID37550653
PMCPMC10408215
OpenAlexW4385619376

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.