ArticleThe Journal of surgical research2023
Design and Development of a Clot Burst Pressure Device to Investigate Resuscitation Strategies.
Article in The Journal of surgical research, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 0 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 2 institutions in 1 country.
Funding
Abstract
introductionA reduction in clot strength is a hallmark feature of trauma-induced coagulopathy. A better understanding of clot integrity can optimize resuscitation strategies. We designed a device to gauge clot strength by pressurizing fluids over a formed clot and measuring the pressure needed to dislodge the clot. We hypothesized that this device could distinguish between clots formed in hypocoagulable and hypercoagulable states by observing differences in the clot burst pressure.
methodsWhole blood from healthy volunteers was collected into sodium citrate tubes and was treated with heparin or fibrinogen to generate clots in a hypocoagulable or hypercoagulable state, respectively. Small bore holes were drilled into polystyrene plates, and recalcified blood was pipetted into the holes. Plates were incubated at 37°C for 30 min to form clots. A pressure cap with an inlet for fluid from a syringe pump and an outlet leading to a measurement column was secured in the wells with a watertight seal.
resultsClot burst pressure was normalized to individual baseline values to account for inherent differences in clot strength. The 1.0 g/L and 2.0 g/L fibrinogen groups were 1.65 ± 0.07 (P = 0.0078) and 2.26 ± 0.16 (P = 0.0078) times as strong as baseline, respectively. The 0.10, 0.15, or 0.20 USP units/mL groups were 0.388 ± 0.07 (P = 0.125), 0.31 ± 0.07 (P = 0.125), 0.21 ± 0.07 (P = 0.125) times as strong as baseline, respectively. Data were analyzed using Wilcoxon matched pairs signed rank testing.
conclusionsThis device tests clot strength using burst pressure, an easily interpreted clinical parameter not measured in existing devices. Future work can test blood from trauma patients to better understand trauma pathophysiology.