Evidence map›Paper›PMID 37548984›Full record

ArticleJAMA internal medicine2023

Effects of Cuff Size on the Accuracy of Blood Pressure Readings: The Cuff(SZ) Randomized Crossover Trial.

Junichi Ishigami, Jeanne Charleston, Edgar R Miller, Kunihiro Matsushita, Lawrence J Appel, Tammy M Brady

Registry-linked trialOpen access · greenAbstract read
In one paragraph

Article in JAMA internal medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04610775 (The Cuff Size Blood Pressure Measurement Trial), which is not on this map. Cited by 42 papers, 7 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
42citing papers in PubMed, 7 pooled it
18.2field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT04610775 nacompletednot on this map

The Cuff Size Blood Pressure Measurement Trial

TypeinterventionalSponsorJohns Hopkins UniversityRan2021 to 2021Enrolled194ConditionsHypertension, Blood Pressure, Cardiovascular Diseases, Cardiovascular Risk FactorArmsOrder of cuff sizes during blood pressure measurements
3 · Its place in the literature

Who cites it

42 citing papers in PubMed, 7 syntheses or guidelines pooled it, 83 citations in OpenAlex.

  1. Guideline
  2. Pooled it
  3. Guideline
  4. CMAJ : Canadian Medical Association journal = journal de l'Association medicale canadienne · 2025
    Guideline
  5. Hypertension Canada guideline for the diagnosis and treatment of hypertension in adults in primary care.CMAJ : Canadian Medical Association journal = journal de l'Association medicale canadienne · 2025
    Guideline
  6. Guideline
  7. Guideline
  8. Review
  9. Article
  10. Disparities in Blood Pressure Measurement.Current hypertension reports · 2026
    Review
  11. Blood pressure measurement techniques.Canadian family physician Medecin de famille canadien · 2026
    Article
  12. Review
  13. Article
  14. Survey on Office Blood Pressure Measurement in Daily Practice in the Hypertension Centers of the Italian Society of Hypertension.High blood pressure & cardiovascular prevention : the official journal of the Italian Society of Hypertension · 2026
    Article
  15. Article
  16. Article
  17. Measuring blood pressure accurately.Australian prescriber · 2026
    Review
  18. Article
  19. Review
  20. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Junichi IshigamiJohns Hopkins Bloomberg School of Public Health, Baltimore, Maryland.
Jeanne CharlestonJohns Hopkins Bloomberg School of Public Health, Baltimore, Maryland.
Edgar R MillerJohns Hopkins Bloomberg School of Public Health, Baltimore, Maryland.
Kunihiro MatsushitaJohns Hopkins Bloomberg School of Public Health, Baltimore, Maryland.
Lawrence J AppelJohns Hopkins Bloomberg School of Public Health, Baltimore, Maryland.
Tammy M BradyJohns Hopkins University School of Medicine, Baltimore, Maryland.
Johns Hopkins University · USJohns Hopkins Medicine · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Importance: Clinical practice guidelines recommend selecting an appropriately sized cuff based on mid-arm circumference prior to measuring blood pressure (BP). To our knowledge, the effect of miscuffing on BP measurement when using an automated BP device has not been quantified. Objective: To determine the effect of using a regular BP cuff vs an appropriately sized BP cuff on automated BP readings. Design, Setting, and Participants: This randomized crossover trial of community-dwelling adults with a wide range of mid-arm circumferences took place between March 16 and October 25, 2021, in Baltimore, Maryland. Participants were recruited via BP screening events at a public food market and a senior housing facility, targeted mailings to prior research participants, placement of study brochures in hypertension clinics at Johns Hopkins University, and referrals from physicians providing hypertension care to adults. Interventions: Participants underwent 4 sets of triplicate BP measurements, with the initial 3 sets using an appropriate, too-small, or too-large BP cuff in random order; the fourth set of triplicate measurements was always completed with an appropriate BP cuff. Main Outcomes and Measures: The primary outcome was the difference in mean BP when measured with a regular BP cuff compared with an appropriate BP cuff. The secondary outcome was the difference in BP when using too-small or too-large BP cuffs vs an appropriate BP cuff across all cuff sizes. Results were also stratified by systolic BP (≥130 mm Hg vs <130 mm Hg) and body mass index (calculated as weight in kilograms divided by height in meters squared; ≥30 vs <30). Results: A total of 195 adults (mean [SD] age, 54 [16] years; 67 [34%] male; 132 [68%] Black; 100 [51%] with hypertension) were randomized for inclusion. Among individuals requiring a small BP cuff, use of a regular BP cuff resulted in a statistically significant lower BP reading (mean systolic BP difference, -3.6 [95% CI, -5.6 to -1.7] mm Hg). In contrast, among individuals requiring a large or extra-large BP cuff, use of a regular BP cuff resulted in a statistically significant higher BP reading (mean systolic BP difference, 4.8 [95% CI, 3.0-6.6] mm Hg and 19.5 [95% CI, 16.1-22.9] mm Hg, respectively). For the secondary outcome, BP differences with overcuffing and undercuffing by 1 and 2 cuff sizes were greater among those requiring larger BP cuffs. The results were consistent in stratified analyses by systolic BP and body mass index. Conclusions and Relevance: In this randomized crossover trial, miscuffing resulted in strikingly inaccurate BP measurements. This is particularly concerning for settings where 1 regular BP cuff size is routinely used in all individuals, regardless of arm size. A renewed emphasis on individualized BP cuff selection is warranted. Trial Registration: ClinicalTrials.gov Identifier: NCT04610775.

Indexed as

HypertensionHypotensionAdultBlood PressureBlood Pressure DeterminationCross-Over StudiesFemaleHumansMaleMiddle Aged

Identifiers

PMID37548984
PMCPMC10407761
OpenAlexW4385620421

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.