ArticleJAMA internal medicine2023
Effects of Cuff Size on the Accuracy of Blood Pressure Readings: The Cuff(SZ) Randomized Crossover Trial.
Article in JAMA internal medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04610775 (The Cuff Size Blood Pressure Measurement Trial), which is not on this map. Cited by 42 papers, 7 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
The Cuff Size Blood Pressure Measurement Trial
Who cites it
42 citing papers in PubMed, 7 syntheses or guidelines pooled it, 83 citations in OpenAlex.
- 10. Cardiovascular Disease and Risk Management: Standards of Care in Diabetes-2026.Diabetes care · 2026Guideline
- Revisiting Unattended Versus Attended Automated Office Blood Pressure Measurements: A Systematic Review and Meta-Analysis.Journal of the American Heart Association · 2025Pooled it
- Hypertension Canada guideline for the diagnosis and treatment of hypertension in adults in primary care.Canadian family physician Medecin de famille canadien · 2025Guideline
- Guideline
- Hypertension Canada guideline for the diagnosis and treatment of hypertension in adults in primary care.CMAJ : Canadian Medical Association journal = journal de l'Association medicale canadienne · 2025Guideline
- Investigation and management of resistant hypertension: British and Irish Hypertension Society position statement.Journal of human hypertension · 2025Guideline
- Guide de pratique clinique en soins de première ligne d'Hypertension Canada pour le diagnostic et le traitement de l'hypertension artérielle chez les adultes.Canadian family physician Medecin de famille canadienGuideline
- Obesity and Cardiovascular Disease: An Obesity Medicine Association (OMA) Clinical Practice Statement (CPS) 2026.Obesity pillars · 2026Review
- Development and validation of a cuff size prediction model for pediatric blood pressure measurement outside the office.Pediatric nephrology (Berlin, Germany) · 2026Article
- Disparities in Blood Pressure Measurement.Current hypertension reports · 2026Review
- Blood pressure measurement techniques.Canadian family physician Medecin de famille canadien · 2026Article
- Leveraging the Electronic Health Record to Identify and Manage Resistant Hypertension.Current hypertension reports · 2026Review
- Rethinking Hypertension Diagnosis in Black Adults: Clinical Challenges and Missed Opportunities.Journal of racial and ethnic health disparities · 2026Article
- Survey on Office Blood Pressure Measurement in Daily Practice in the Hypertension Centers of the Italian Society of Hypertension.High blood pressure & cardiovascular prevention : the official journal of the Italian Society of Hypertension · 2026Article
- Factors affecting hospital inpatient blood pressure measurement as ranked by a Delphi survey.Scientific reports · 2026Article
- Factors Associated With Discordant Blood Pressure Measures among Very Old Adults: Results From the Atherosclerosis Risk in Communities (ARIC) Study.Hypertension (Dallas, Tex. : 1979) · 2026Article
- Measuring blood pressure accurately.Australian prescriber · 2026Review
- Blood Pressure Estimation Through Pulse Wave Analysis Using Features Extracted from Carotid Diameter Distension Waveforms.Biosensors · 2026Article
- Cuffless Devices for the Measurement of Blood Pressure: A Scientific Statement From the American Heart Association.Hypertension (Dallas, Tex. : 1979) · 2026Review
- Comparison of two validated oscillometric devices in a home-like setup reveals pronounced blood pressure differences and reduced precision.Hypertension research : official journal of the Japanese Society of Hypertension · 2026Article
Corrections and comments
- Commented on by
- Commented on by
- Commented on by
- Commented on by
- Commented on by
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Importance: Clinical practice guidelines recommend selecting an appropriately sized cuff based on mid-arm circumference prior to measuring blood pressure (BP). To our knowledge, the effect of miscuffing on BP measurement when using an automated BP device has not been quantified. Objective: To determine the effect of using a regular BP cuff vs an appropriately sized BP cuff on automated BP readings. Design, Setting, and Participants: This randomized crossover trial of community-dwelling adults with a wide range of mid-arm circumferences took place between March 16 and October 25, 2021, in Baltimore, Maryland. Participants were recruited via BP screening events at a public food market and a senior housing facility, targeted mailings to prior research participants, placement of study brochures in hypertension clinics at Johns Hopkins University, and referrals from physicians providing hypertension care to adults. Interventions: Participants underwent 4 sets of triplicate BP measurements, with the initial 3 sets using an appropriate, too-small, or too-large BP cuff in random order; the fourth set of triplicate measurements was always completed with an appropriate BP cuff. Main Outcomes and Measures: The primary outcome was the difference in mean BP when measured with a regular BP cuff compared with an appropriate BP cuff. The secondary outcome was the difference in BP when using too-small or too-large BP cuffs vs an appropriate BP cuff across all cuff sizes. Results were also stratified by systolic BP (≥130 mm Hg vs <130 mm Hg) and body mass index (calculated as weight in kilograms divided by height in meters squared; ≥30 vs <30). Results: A total of 195 adults (mean [SD] age, 54 [16] years; 67 [34%] male; 132 [68%] Black; 100 [51%] with hypertension) were randomized for inclusion. Among individuals requiring a small BP cuff, use of a regular BP cuff resulted in a statistically significant lower BP reading (mean systolic BP difference, -3.6 [95% CI, -5.6 to -1.7] mm Hg). In contrast, among individuals requiring a large or extra-large BP cuff, use of a regular BP cuff resulted in a statistically significant higher BP reading (mean systolic BP difference, 4.8 [95% CI, 3.0-6.6] mm Hg and 19.5 [95% CI, 16.1-22.9] mm Hg, respectively). For the secondary outcome, BP differences with overcuffing and undercuffing by 1 and 2 cuff sizes were greater among those requiring larger BP cuffs. The results were consistent in stratified analyses by systolic BP and body mass index. Conclusions and Relevance: In this randomized crossover trial, miscuffing resulted in strikingly inaccurate BP measurements. This is particularly concerning for settings where 1 regular BP cuff size is routinely used in all individuals, regardless of arm size. A renewed emphasis on individualized BP cuff selection is warranted. Trial Registration: ClinicalTrials.gov Identifier: NCT04610775.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.