Evidence map›Paper›PMID 37547807›Full record

ArticleJournal of multidisciplinary healthcare2023

Smart Glasses to Facilitate Ultrasound Guided Peripheral Intravenous Access in the Simulation Setting for Thai Emergency Medical Service Providers.

Kamonwon Ienghong, Lap Woon Cheung, Pornpawit Wongwan, Korakot Apiratwarakul

Abstract read
In one paragraph

Article in Journal of multidisciplinary healthcare, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Trial
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Kamonwon IenghongDepartment of Emergency Medicine, Faculty of Medicine, Khon Kaen University, Khon Kaen, Thailand.ORCID 0000-0003-0328-4128
Lap Woon CheungAccident & Emergency Department, Princess Margaret Hospital, Kowloon, Hong Kong.ORCID 0000-0002-7089-9125
Pornpawit WongwanDepartment of Emergency Medicine, Faculty of Medicine, Khon Kaen University, Khon Kaen, Thailand.
Korakot ApiratwarakulDepartment of Emergency Medicine, Faculty of Medicine, Khon Kaen University, Khon Kaen, Thailand.ORCID 0000-0002-1984-0865

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: The ultrasound-guided peripheral venous access (USGPIV) was reported as difficult for novices to perform. Smart glasses equipped with teleconference systems can display real-time ultrasound images to sonographers and consultants which can increase the success rate of this procedure. The purpose of this study was to assess the effectiveness of employing smart glasses for USGPIV. Patients and Methods: A randomized, simulation study was conducted in emergency medical service (EMS) providers at Srinagarind Hospital, Thailand, from January to April 2023. We randomized participants into two groups which included participants who wore smart glasses during procedures requiring USGPIV (the smart glasses group) and participants who performed USGPIV with no smart glasses (the non-smart glasses group). After participating in USGPIV cannulation training, the simulations were carried out. The primary outcome was the first-attempt success rate, with secondary outcomes including the procedure time and subjective difficulty. Results: Fifty participants were recruited for the study. The smart glasses group was superior to the non-smart glasses group both in terms of first-attempt success rate with no statistically significant (64% vs 60%; P = 0.460) and also demonstrated a shorter procedure time than the non-smart glasses group (25.5 sec vs 42.3 sec; P = 0.003). The participants reported the subjective difficulty score was higher in the smart glasses group (the visual analog scale, VAS = 8). Conclusion: In simulation scenarios, the smart glasses-assisted USGPIV could shorten the procedure time. However, our study did not find significant differences in the first pass success rate of USGPIV between the two groups.

Indexed as

emergency medical servicessmart glassesultrasonography

Identifiers

PMID37547807
PMCPMC10404035

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.