Evidence map›Paper›PMID 37547054›Full record

ArticleBMJ neurology open2023

Out-of-hospital multimodal seizure detection: a pilot study.

Jonas Munch Nielsen, Ástrós Eir Kristinsdóttir, Ivan Chrilles Zibrandtsen, Paolo Masulli, Martin Ballegaard, Tobias Søren Andersen, Troels Wesenberg Kjær

Abstract read
In one paragraph

Article in BMJ neurology open, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Seizure Detection Devices.Journal of clinical medicine · 2025
    Review
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Jonas Munch NielsenDepartment of Neurology, Zealand University Hospital Roskilde, Roskilde, Denmark.
Ástrós Eir KristinsdóttirDepartment of Neurology, Zealand University Hospital Roskilde, Roskilde, Denmark.
Ivan Chrilles ZibrandtsenDepartment of Neurology, Zealand University Hospital Roskilde, Roskilde, Denmark.
Paolo MasulliDepartment of Applied Mathematics and Computer Science, Technical University, Lyngby, Denmark.
Martin BallegaardDepartment of Neurology, Zealand University Hospital Roskilde, Roskilde, Denmark.ORCID 0000-0003-3594-1997
Tobias Søren AndersenDepartment of Applied Mathematics and Computer Science, Technical University, Lyngby, Denmark.
Troels Wesenberg KjærDepartment of Neurology, Zealand University Hospital Roskilde, Roskilde, Denmark.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Out-of-hospital seizure detection aims to provide clinicians and patients with objective seizure documentation in efforts to improve the clinical management of epilepsy. In-patient studies have found that combining different modalities helps improve the seizure detection accuracy. In this study, the objective was to evaluate the viability of out-of-hospital seizure detection using wearable ECG, accelerometry and behind-the-ear electroencephalography (EEG). Furthermore, we examined the signal quality of out-of-hospital EEG recordings. Methods: Seventeen patients were monitored for up to 5 days. A support vector machine based seizure detection algorithm was applied using both in-patient seizures and out-of-hospital electrographic seizures in one patient. To assess the content of noise in the EEG signal, we compared the root-mean-square (RMS) of the recordings to a reference threshold derived from manually categorised segments of EEG recordings. Results: In total 1427 hours of continuous EEG was recorded. In one patient, we identified 15 electrographic focal impaired awareness seizures with a motor component. After training our algorithm on in-patient data, we found a sensitivity of 91% and a false alarm rate (FAR) of 18/24 hours for the detection of out-of-hospital seizures using a combination of EEG and ECG recordings. We estimated that 30.1% of the recorded EEG signal was physiological EEG, with an RMS value within the reference threshold. Conclusion: We found that detection of out-of-hospital focal impaired awareness seizures with a motor component is possible and that applying multiple modalities improves the diagnostic accuracy compared with unimodal EEG. However, significant challenges remain regarding a high FAR and that only 30.1% of the EEG data represented usable signal.

Indexed as

EEGEPILEPSYNEUROPHYSIOLOGY

Identifiers

PMID37547054
PMCPMC10401242

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.