ArticleJournal of artificial organs : the official journal of the Japanese Society for Artificial Organs2024
Abnormal stenosis of a drainage cannula due to excessive negative pressure during venovenous extracorporeal membrane oxygenation management: a case report.
Article in Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 2 citations in OpenAlex.
- Arterial oxygen pressure during veno-venous extracorporeal membrane oxygenation may be increased by advancing the tip of the drainage cannula into the superior vena cava: a case report.Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2025Article
- Potential new treatment for inferior vena cava injury using extracorporeal membrane oxygenation applying flow diversion effect.Trauma surgery & acute care open · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
We report a case in which excessive negative pressure may have been applied to the proximal side hole of a drainage cannula during venovenous extracorporeal membrane oxygenation (V-V ECMO), resulting in abnormal stenosis of the drainage cannula. V-V ECMO was introduced in a 71-year-old male patient who was transferred from another hospital for severe respiratory failure associated with varicella pneumonia and acute respiratory distress syndrome. Drainage was performed using a PCKC-V™ 24Fr (MERA, Japan) cannula via the right femoral vein with the tip of the cannula near the level of the diaphragm under fluoroscopy. Reinfusion was performed via the right internal jugular vein. Due to poor systemic oxygenation, the drainage cannula was withdrawn caudally and refixed to reduce the effect of recirculation. Two days later, drainage pressure dropped rapidly, and frequent ECMO flow interruption occurred due to poor drainage. An abdominal X-ray revealed abnormal stenosis of the proximal side hole site of the drainage cannula. We diagnosed that the drainage cannula was damaged, and it was replaced with another, namely a Medtronic Bio-Medicus™ 25 Fr (GETINGE, Sweden) cannula. However, the removed drainage cannula was not damaged, suggesting that the cannula was temporarily stenosed by momentary excessive negative pressure. In a multi-stage drainage cannula, the main drainage site is the proximal side hole, with little negative pressure applied at the apical foramen in a mock experimental ex vivo drainage test in a water tank. Hence, improvement of a multi-stage drainage cannula is recommended, such as adequate reinforcement of the side hole site with a wire.