Evidence map›Paper›PMID 37542111›Full record

ArticleScientific reports2023

Passive performance evaluation and validation of a viscous impeller pump for subpulmonary fontan circulatory support.

Weiguang Yang, Timothy A Conover, Richard S Figliola, Guruprasad A Giridharan, Alison L Marsden, Mark D Rodefeld

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
3.0field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 14 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Frontiers in bioengineering and biotechnology · 2025
    Article
  5. Article
  6. Article
  7. Current Understanding and Future Directions of Transcatheter Devices to Assist Failing Fontan.Journal of the Society for Cardiovascular Angiography & Interventions · 2024
    Review
  8. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 1 country.

Weiguang YangDepartment of Pediatrics (Cardiology), Stanford University, Stanford, CA, USA. wgyang@stanford.edu.
Timothy A ConoverDepartments of Mechanical Engineering, Clemson University, Clemson, SC, USA.
Richard S FigliolaDepartments of Mechanical Engineering, Clemson University, Clemson, SC, USA.
Guruprasad A GiridharanDepartment of Bioengineering, University of Louisville, Louisville, KY, USA.
Alison L MarsdenDepartment of Pediatrics (Cardiology), Stanford University, Stanford, CA, USA.
Mark D RodefeldSection of Cardiothoracic Surgery, Department of Surgery, Indiana University School of Medicine, Indianapolis, IN, USA.
Clemson University · USStanford University · USIndiana University – Purdue University Indianapolis · USUniversity of Louisville · US

Funding

Cavopulmonary Assist to Reverse the FontanR01HL150346 · NHLBI · INDIANA UNIVERSITY INDIANAPOLIS · PI RODEFELD, MARK D · 2020 to 2023
$8.9M
NHLBI NIH HHS R01 HL150346
6 · The paper itself

Abstract

Patients with single ventricle defects undergoing the Fontan procedure eventually face Fontan failure. Long-term cavopulmonary assist devices using rotary pump technologies are currently being developed as a subpulmonary power source to prevent and treat Fontan failure. Low hydraulic resistance is a critical safety requirement in the event of pump failure (0 RPM) as a modest 2 mmHg cavopulmonary pressure drop can compromise patient hemodynamics. The goal of this study is therefore to assess the passive performance of a viscous impeller pump (VIP) we are developing for Fontan patients, and validate flow simulations against in-vitro data. Two different blade heights (1.09 mm vs 1.62 mm) and a blank housing model were tested using a mock circulatory loop (MCL) with cardiac output ranging from 3 to 11 L/min. Three-dimensional flow simulations were performed and compared against MCL data. In-silico and MCL results demonstrated a pressure drop of < 2 mmHg at a cardiac output of 7 L/min for both blade heights. There was good agreement between simulation and MCL results for pressure loss (mean difference - 0.23 mmHg 95% CI [0.24-0.71]). Compared to the blank housing model, low wall shear stress area and oscillatory shear index on the pump surface were low, and mean washout times were within 2 s. This study demonstrated the low resistance characteristic of current VIP designs in the failed condition that results in clinically acceptable minimal pressure loss without increased washout time as compared to a blank housing model under normal cardiac output in Fontan patients.

Indexed as

Fontan ProcedureCardiac OutputHeart DiseasesHumansLung

Identifiers

PMID37542111
PMCPMC10403595
OpenAlexW4385580307

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.