Fluorescent immunochromatographic test strip for therapeutic drug monitoring of methotrexate with high sensitivity and wide dynamic range.

Zhongjie Zhu, Yu Zhang, Jinxia Xue, Jing Kong, Ling Huang, Hui Ouyang, Zhifeng Fu, Yong He

Abstract read
PubMed Publisher
In one paragraph

Article in Mikrochimica acta, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
1.4field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 5 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Zhongjie ZhuDepartment of Pharmacy, The Second Affiliated Hospital of Zunyi Medical University, Zunyi, 563000, Guizhou Province, China.
Yu ZhangCollege of Pharmaceutical Sciences, Southwest University, Chongqing, 400715, China.
Jinxia XueCollege of Pharmaceutical Sciences, Southwest University, Chongqing, 400715, China.
Jing KongDepartment of Pharmacy, Affiliated Hospital of Zunyi Medical University, Zunyi, 563000, Guizhou Province, China.
Ling HuangDepartment of Pharmacy, The Second Affiliated Hospital of Zunyi Medical University, Zunyi, 563000, Guizhou Province, China.
Hui OuyangCollege of Pharmaceutical Sciences, Southwest University, Chongqing, 400715, China.
Zhifeng FuCollege of Pharmaceutical Sciences, Southwest University, Chongqing, 400715, China. fuzf@swu.edu.cn.
Yong HeDepartment of Pharmacy, The Second Affiliated Hospital of Zunyi Medical University, Zunyi, 563000, Guizhou Province, China. heyongzmu@163.com.ORCID http://orcid.org/0000-0002-1741-5363
Southwest University · CNZunyi Medical University · CN

Funding

National Natural Science Foundation of China 21964023
6 · The paper itself

Abstract

As a front-line chemotherapeutic drug for maintenance and consolidation therapy, methotrexate (MTX) has widely been applied to treat various tumors and some inflammatory diseases. However, because of its severe toxicity ascribed to low selectivity, it is necessary to monitor therapeutic drugs in high-dose MTX therapeutic regimens to ensure treatment safety. In this work, we developed a fluorescent immunochromatographic test strip (FITS) for monitoring MTX by employing time-resolved fluorescent microspheres as signal probes. With a competitive immunoassay mode, the FITS for MTX shows a super-wide dynamic range of 10 pM-10 μM, covering the entire clinical therapeutic concentration range of MTX. Therapeutic drug monitoring of MTX can be achieved within 7 min with high specificity, facilitating the timely rescue of drug poisoning led by high-dose MTX treatment. The method was employed for monitoring MTX in the spiked human serum, urine, and milk, showing acceptable recoveries ranging from 94.0 to 110.0%. The established FITS has been applied to MTX detection in serum obtained from high-dose MTX treatment. The results from FITS and enzyme multiplied immunoassay technique showed no significant difference, suggesting its reliability for usage in real biological samples. The device shows promise in point-of-care therapeutic drug monitoring for resource-limited countries and institutes, which significantly facilitates overcoming the lag time between sampling and results.

Indexed as

MethotrexateNeoplasmsDrug MonitoringHumansMicrospheresReproducibility of ResultsMethotrexateFluorescence detectionImmunochromatographic test stripMethotrexatePoint-of-care testingTherapeutic drug monitoring

Identifiers

PMID37540283
OpenAlexW4385564707

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.