Evidence map›Paper›PMID 37539615›Full record

ArticleActa bio-medica : Atenei Parmensis2023

Revision of total knee arthroplasty with press-fit condylar SIGMA TC3-mobile bearing system and porous metaphyseal sleeves in type AORI type II and III bone defects. A long-term follow-up study.

Fabio Zanchini, Davide Piscopo, Enrico Pola, Valerio Cipolloni, Antonio Piscopo, Stefano Cacciapuoti, Gabriele Colò, Federico Fusini

Open access · greenAbstract read
In one paragraph

Article in Acta bio-medica : Atenei Parmensis, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 77% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 8 institutions in 3 countries.

Fabio Zanchini. fabio.zanc@libero.it.
Davide Piscopo. davide.pisc@gmail.com.
Enrico Pola. e.pola@live.com.
Valerio Cipolloni. valeriocipolloni@gmail.com.
Antonio PiscopoDepartment of Orthopedics and Traumatology, Sacro Cuore di Gesù Fatebenefratelli Hospital, Benevento, Italy. antonio.piscopo@fbfbn.it.
Stefano Cacciapuoti. cacciapuoti.stef@gmail.com.
Gabriele Colò. gabriele.colo@yahoo.it.
Federico FusiniDepartment of Orthopaedic and Traumatology, Orthopaedic and Trauma Center, University of Turin, via Zuretti 29, 10121, Turin. fusinif@hotmail.com.
CTO Hospital · ITFatebenefratelli Hospital · ITFeminist Archive North · GBInstitute for Community Living · USiRobot (United States) · USJisc · GBValve (United States) · USYahoo (United Kingdom) · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND AND

aimRevision total knee arthroplasty(rTKA) is a challenging and expensive treatment for orthopedic surgeons who have to deal with poor bone quality and bone loss. This study aims to retrospectively evaluate the clinical and radiological results of patients undergoing rTKA and porous metaphyseal sleeves in AORI type II and III bone defects.

methodsWe conducted a retrospective series of continuous patients treated for mechanical failure of TKA. All patients with aseptic loosening of TKR underwent revision arthroplasty. We included only patients with AORI type IIa/b and III bone defects. The Septic revision or other grades of bone defect or patients lost at follow-up or with less than 2 years follow-up were excluded. We evaluated knee function with Oxford Knee Score (OKS) pain with Visual Analogue Scale (VAS) and range of motion (flex-ext), while radiological evaluation was performed to evaluate any sign of loosening.

resultsThe mean preoperative OKS was 13.85 +/- 5.39 (range 5 -22), and it improved to 33.89 +/- 3.98 (range 20 - 40) (p<0.00001). The mean preoperative VAS was 7.77 +/- 1.33 (range 5 - 9), and it improved to 1.89 +/- 0.92 (range 0 - 4) (p<0.00001). ROM improved from 62.23° +/- 13.71° (range 40° - 90°) to 100.53° +/- 6.93° (range 90° - 120°) (p<0.00001). No signs of loosening or implant migration were reported.

conclusionsMetaphyseal sleeves made knee revision in large bone defects reliable and effective with good results. Good implant stability was reached in all the cases treated with metaphyseal sleeves.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisFollow-Up StudiesHumansPorosityProsthesis DesignReoperationRetrospective Studies

Identifiers

PMID37539615
PMCPMC10440776
OpenAlexW4385563988

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.