Evidence map›Paper›PMID 37537304›Full record

ArticleNature biomedical engineering2023

Soft and stretchable organic bioelectronics for continuous intraoperative neurophysiological monitoring during microsurgery.

Wenjianlong Zhou, Yuanwen Jiang, Qin Xu, Liangpeng Chen, Hui Qiao, Yi-Xuan Wang, Jian-Cheng Lai, Donglai Zhong, Yuan Zhang, Weining Li and 13 more

Abstract read
PubMed Publisher
In one paragraph

Article in Nature biomedical engineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
6.7field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 45 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Ionic-Bionic Interfaces: Advancing Iontronic Strategies for Bioelectronic Sensing and Therapy.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Evaporative Morphology Tuning of Conducting Polymer Films Under Controlled Vacuum Conditions.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025
    Article
  11. Symmetry engineering in 2D bioelectronics facilitating augmented biosensing interfaces.Proceedings of the National Academy of Sciences of the United States of America · 2024
    Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

23 authors at 5 institutions in 2 countries.

Wenjianlong Zhou *Department of Neurosurgery, Beijing Tiantan Hospital, National Center for Neurological Disorders, Capital Medical University, Beijing, China.
Yuanwen Jiang *Department of Chemical Engineering, Stanford University, Stanford, CA, USA.
Qin XuDepartment of Neurosurgery, Beijing Tiantan Hospital, National Center for Neurological Disorders, Capital Medical University, Beijing, China.
Liangpeng ChenDepartment of Neurosurgery, Beijing Tiantan Hospital, National Center for Neurological Disorders, Capital Medical University, Beijing, China.
Hui QiaoDepartment of Neurophysiology, Beijing Neurosurgical Institute, Capital Medical University, Beijing, China.
Yi-Xuan WangTianjin Key Laboratory of Molecular Optoelectronic Sciences, Department of Chemistry, School of Science, Tianjin University, Tianjin, China.
Jian-Cheng LaiDepartment of Chemical Engineering, Stanford University, Stanford, CA, USA.
Donglai ZhongDepartment of Chemical Engineering, Stanford University, Stanford, CA, USA.ORCID http://orcid.org/0000-0002-0876-414X
Yuan ZhangDepartment of Neurosurgery, Beijing Tiantan Hospital, National Center for Neurological Disorders, Capital Medical University, Beijing, China.
Weining LiDepartment of Electronic Engineering, Tsinghua University, Beijing, China.
Yanru DuDepartment of Pathology, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.
Xuecheng WangDepartment of Electronic Engineering, Tsinghua University, Beijing, China.
Jiaxin LeiDepartment of Electronic Engineering, Tsinghua University, Beijing, China.
Gehong DongDepartment of Pathology, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.
Xiudong GuanDepartment of Neurosurgery, Beijing Tiantan Hospital, National Center for Neurological Disorders, Capital Medical University, Beijing, China.
Shunchang MaDepartment of Neurosurgery, Beijing Tiantan Hospital, National Center for Neurological Disorders, Capital Medical University, Beijing, China.
Peng KangDepartment of Neurosurgery, Beijing Tiantan Hospital, National Center for Neurological Disorders, Capital Medical University, Beijing, China.
Linhao YuanDepartment of Neurosurgery, Beijing Tiantan Hospital, National Center for Neurological Disorders, Capital Medical University, Beijing, China.
Milin ZhangDepartment of Electronic Engineering, Tsinghua University, Beijing, China.
Jeffrey B-H TokDepartment of Chemical Engineering, Stanford University, Stanford, CA, USA.ORCID http://orcid.org/0000-0002-2794-0663
Deling LiDepartment of Neurosurgery, Beijing Tiantan Hospital, National Center for Neurological Disorders, Capital Medical University, Beijing, China. ttyyneuroli@126.com.ORCID http://orcid.org/0000-0002-4300-7136
Zhenan BaoDepartment of Chemical Engineering, Stanford University, Stanford, CA, USA. zbao@stanford.edu.ORCID http://orcid.org/0000-0002-0972-1715
Wang JiaDepartment of Neurosurgery, Beijing Tiantan Hospital, National Center for Neurological Disorders, Capital Medical University, Beijing, China. jwttyy@126.com.ORCID http://orcid.org/0000-0002-0992-6702
Capital Medical University · CNStanford University · USTsinghua University · CNBeijing Tian Tan Hospital · CNTianjin University · CN

Funding

National Natural Science Foundation of China (National Science Foundation of China) 82071996National Science Foundation (NSF) ECCS-2026822
6 · The paper itself

Abstract

In microneurosurgery, it is crucial to maintain the structural and functional integrity of the nerve through continuous intraoperative identification of neural anatomy. To this end, here we report the development of a translatable system leveraging soft and stretchable organic-electronic materials for continuous intraoperative neurophysiological monitoring. The system uses conducting polymer electrodes with low impedance and low modulus to record near-field action potentials continuously during microsurgeries, offers higher signal-to-noise ratios and reduced invasiveness when compared with handheld clinical probes for intraoperative neurophysiological monitoring and can be multiplexed, allowing for the precise localization of the target nerve in the absence of anatomical landmarks. Compared with commercial metal electrodes, the neurophysiological monitoring system allowed for enhanced post-operative prognoses after tumour-resection surgeries in rats. Continuous recording of near-field action potentials during microsurgeries may allow for the precise identification of neural anatomy through the entire procedure.

Indexed as

Intraoperative Neurophysiological MonitoringMicrosurgeryAction PotentialsAnimalsElectrodesMalePolymersRatsRats, Sprague-DawleySignal-To-Noise RatioPolymers

Identifiers

PMID37537304
OpenAlexW4385556064

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.