Evidence map›Paper›PMID 37536733›Full record

ArticleAJNR. American journal of neuroradiology2023

Iterative Denoising Accelerated 3D FLAIR Sequence for Hydrops MR Imaging at 3T.

R Quint, A Vaussy, A Stemmer, C Hautefort, E Houdart, M Eliezer

Abstract read
In one paragraph

Article in AJNR. American journal of neuroradiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

R QuintFrom the Department of Neuroradiology (R.Q., E.H., M.E.), Lariboisière University Hospital, Paris, France.ORCID 0000-0002-2205-1111
A VaussySiemens Healthineers France (A.V.), Saint-Denis, France.ORCID 0000-0002-8612-2150
A StemmerSiemens Healthineers (A.S.), Erlangen, Germany.ORCID 0000-0002-3016-3498
C HautefortDepartment of Head and Neck Surgery (C.H.), Lariboisière University Hospital, Paris, France.ORCID 0000-0002-5056-5136
E HoudartFrom the Department of Neuroradiology (R.Q., E.H., M.E.), Lariboisière University Hospital, Paris, France.ORCID 0000-0002-8109-5501
M EliezerFrom the Department of Neuroradiology (R.Q., E.H., M.E.), Lariboisière University Hospital, Paris, France michael.eliezer@aphp.fr.ORCID 0000-0002-4973-1790

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purpose3D FLAIR sequences have become the criterion standard for identifying endolymphatic hydrops, but scan time remains an important limitation to their widespread use. Our purpose was to evaluate the diagnostic performance and image quality of an accelerated 3D FLAIR sequence combined with an iterative denoising algorithm. MATERIALS AND

methodsThis was a retrospective study performed on 30 patients with clinical suspicion of endolymphatic hydrops who underwent 3T MR imaging 4 hours after gadolinium injection using two 3D FLAIR sequences. The first (conventional FLAIR) was accelerated with a conventional turbo factor of 187. The second was accelerated with an increased turbo factor of 263, resulting in a 33% scan time reduction (5 minutes 36 seconds versus 8 minutes 15 seconds, respectively). A sequence was reconstructed in-line immediately after the accelerated 3D FLAIR acquisition from the same raw data with iterative denoising (accelerated-FLAIR iterative denoising). The signal intensity ratio image quality score and endolymphatic hydrops diagnosis were evaluated.

resultsThe mean signal intensity ratio for symptomatic and asymptomatic ears of accelerated-FLAIR iterative denoising was significantly higher than the mean SNR of conventional FLAIR (29.5 versus 19 and 25.9 versus 16.3,

conclusionsThe iterative denoising algorithm applied to an accelerated 3D FLAIR sequence for exploration of endolymphatic hydrops enabled significantly reducing the scan time without compromising image quality and diagnostic performance.

Indexed as

Contrast MediaEndolymphatic HydropsEdemaHumansImaging, Three-DimensionalMagnetic Resonance ImagingRetrospective StudiesContrast Media

Identifiers

PMID37536733
PMCPMC10494947

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.