ArticleAnnals of rehabilitation medicine2023
Validation of Wearable Digital Devices for Heart Rate Measurement During Exercise Test in Patients With Coronary Artery Disease.
Article in Annals of rehabilitation medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 22 citations in OpenAlex.
- The Representation of Different Populations in Studies Assessing the Validity of Consumer Wearable Photoplethysmography-Based Measurements: Scoping Review.JMIR mHealth and uHealth · 2026Article
- Comparison of heart rate measurement accuracy among commercially available photoplethysmography-based wearable devices across exercise intensities.Physical activity and nutrition · 2026Article
- Heart Rate Estimation Using the Galaxy Watch During Maximal Cardiopulmonary Exercise Testing: Cross-Sectional Validation Study.JMIR cardio · 2026Article
- The accuracy of Apple Watch measurements: a living systematic review and meta-analysis.NPJ digital medicine · 2026Article
- Physiological load estimation in athletes using ECG-derived features and gradient-boosted modeling.Frontiers in public health · 2026Article
- Validation of heart rate measured by the consumer-level wearable device Fitbit: a cross-sectional observational study.Journal of physical therapy science · 2025Article
- Article
- Article
- Evaluating the Accuracy of Low-Cost Wearable Sensors for Healthcare Monitoring.Micromachines · 2025Article
- Wearable Devices for Exercise Prescription and Physical Activity Monitoring in Patients with Various Cardiovascular Conditions.CJC open · 2025Review
- Prognostic Factors for Responders of Home-Based Pulmonary Rehabilitation-Secondary Analysis of a Randomized Controlled Trial.Healthcare (Basel, Switzerland) · 2025Article
- The Accessibility and Effect of Cardiac Rehabilitation in COVID-19 Pandemic Era.Annals of rehabilitation medicine · 2024Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveTo assess the accuracy of recently commercialized wearable devices in heart rate (HR) measurement during cardiopulmonary exercise test (CPX) under gradual increase in exercise intensity, while wearable devices with HR monitors are reported to be less accurate in different exercise intensities.
methodsCPX was performed for patients with coronary artery disease (CAD). Twelve lead electrocardiograph (ECG) was the gold standard and Apple watch 7 (AW7), Galaxy watch 4 (GW4) and Bio Patch Mobicare 200 (MC200) were applied for comparison. Paired absolute difference (PAD), mean absolute percentage error (MAPE) and intraclass correlation coefficient (ICC) were evaluated for each device.
resultsForty-four participants with CAD were included. All the devices showed MAPE under 2% and ICC above 0.9 in rest, exercise and recovery phases (MC200=0.999, GW4=0.997, AW7=0.998). When comparing exercise and recovery phase, PAD of MC200 and AW7 in recovery phase were significantly bigger than PAD of exercise phase (p<0.05). Although not significant, PAD of GW4 tended to be bigger in recovery phase, too. Also, when stratified by HR 20, ICC of all the devices were highest under HR of 100, and ICC decreased as HR increased. However, except for ICC of GW4 at HR above 160 (=0.867), all ICCs exceeded 0.9 indicating excellent accuracy.
conclusionThe HR measurement of the devices validated in this study shows a high concordance with the ECG device, so CAD patients may benefit from the devices during high-intensity exercise under conditions where HR is measured reliably.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials