Evidence map›Paper›PMID 37535637›Full record

ArticlePloS one2023

Reduction of aerosol dissemination in a dental area generated by high-speed and scaler ultrasonic devices employing the "Prime Protector".

Esthelvia Carolina Guzmán-Flores, Amparo Rocío Fuentes-Ayala, Alicia Consuelo Martínez-Martínez, Daniela Estefanía Aguayo-Félix, Margarita Valeria Arellano-Osorio, Martín Campuzano-Donoso, Náthaly Mercedes Román-Galeano, Melanie Llerena-Velásquez, Yajaira Vásquez-Tenorio

Abstract read
In one paragraph

Article in PloS one, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Esthelvia Carolina Guzmán-FloresSchool of Dentistry, Faculty of Medical Sciences, International University of Ecuador, Quito, Ecuador.ORCID 0000-0002-3440-6266
Amparo Rocío Fuentes-AyalaSchool of Dentistry, Faculty of Medical Sciences, International University of Ecuador, Quito, Ecuador.
Alicia Consuelo Martínez-MartínezSchool of Dentistry, Faculty of Medical Sciences, International University of Ecuador, Quito, Ecuador.
Daniela Estefanía Aguayo-FélixSchool of Dentistry, Faculty of Medical Sciences, International University of Ecuador, Quito, Ecuador.
Margarita Valeria Arellano-OsorioSchool of Dentistry, Faculty of Medical Sciences, International University of Ecuador, Quito, Ecuador.
Martín Campuzano-DonosoSchool of Dentistry, Faculty of Medical Sciences, International University of Ecuador, Quito, Ecuador.ORCID 0000-0001-5317-8548
Náthaly Mercedes Román-GaleanoSchool of Dentistry, Faculty of Medical Sciences, International University of Ecuador, Quito, Ecuador.ORCID 0000-0002-6417-5550
Melanie Llerena-VelásquezSchool of Dentistry, Faculty of Medical Sciences, International University of Ecuador, Quito, Ecuador.
Yajaira Vásquez-TenorioSchool of Dentistry, Faculty of Medical Sciences, International University of Ecuador, Quito, Ecuador.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The use of an external dome aerosol containment device (Prime Protector) is proposed to reduce the spread of particles within the dental office. Hence, the aim of our study was to compare the spread of bioaerosols generated by a High-speed Handpiece (HH) and an Ultrasonic Prophylaxis Device (UPD), with and without the Prime Protector dome (PP) by counting Colony Forming Units (CFU) of Lactobacillus casei Shirota, at different distances on the x and y axis. The PP was located considering the parallelism between the base of the dome and the frontal plane of the simulator, aligning the center of the mouth with the center of the dome. The PP dome measurements are 560.0mm x 255.0mm x 5mm. Petri dishes were placed at 0.5 m, 1 m and 1.5 m respectively. Aerosol generation in the laboratory environment was done three times with the following experimental groups 1) HH, 2) HH-PP, 3) UPD, 4) UPD-PP. Each dental device activation (HH and UPD) had a time frame of 2 minutes on the upper anterior teeth of the dental phantom with a liquid suspension containing Lactobacillus casei Shirota (YAKULT 0836A 0123; 1027F 0407). Air pressure and ventilation were parameterized. No separate high-volume evacuation used, nor was there any air removal attached to the dome. Results showed no significant difference between distance and axis in the CFU count. When means for devices and distances were compared between each of them all showed significant differences except for UPD and UPD-PP (p <0,004). In conclusion, external devices like Prime Protector could help decrease aerosol diffusion during high-speed handpiece activation. However, this dome does not replace the use of PPE inside dental clinics.

Indexed as

Dental ScalingAerosolsDental OfficesHumansMouthOccupational ExposurePersonal Protective EquipmentUltrasonicsAerosols

Identifiers

PMID37535637
PMCPMC10399923

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked