Evidence map›Paper›PMID 37535276›Full record

ArticleJournal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology2023

Combined femoral and tibial component total knee arthroplasty device rotation measurement is reliable and predicts clinical outcome.

José A Hernández-Hermoso, Lexa Nescolarde, Federico Yañez-Siller, Juan Calle-García, Damian Garcia-Perdomo, Ricard Pérez-Andres

Abstract read
In one paragraph

Article in Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers, 5 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed, 5 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 5 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Pooled it
  5. Pooled it
  6. Trial
  7. Trial
  8. Review
  9. Article
  10. Article
  11. Article
  12. Review
  13. Article
  14. Article
  15. Article
  16. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

José A Hernández-HermosoDepartment of Orthopedic Surgery and Traumatology, Hospital Universitari Germans Trias i Pujol, Carretera Canyet s/n, 08916, Badalona, Barcelona, Spain. dr.hernandezhermoso@gmail.com.ORCID http://orcid.org/0000-0002-9167-3782
Lexa NescolardeBiomedical Engineering, Department of Electronic Universitat Politècnica de Catalunya, Barcelona, Spain.
Federico Yañez-SillerDepartment of Orthopedic Surgery and Traumatology, Hospital Universitari Germans Trias i Pujol, Carretera Canyet s/n, 08916, Badalona, Barcelona, Spain.
Juan Calle-GarcíaDepartment of Orthopedic Surgery and Traumatology, Hospital Universitari Germans Trias i Pujol, Carretera Canyet s/n, 08916, Badalona, Barcelona, Spain.
Damian Garcia-PerdomoDepartment of Radiology, Hospital, Universitari Germans Trias i Pujol, Carretera Canyet s/n, 08916, Badalona, Barcelona, Spain.
Ricard Pérez-AndresDepartment of Radiology, Hospital, Universitari Germans Trias i Pujol, Carretera Canyet s/n, 08916, Badalona, Barcelona, Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe optimal total knee arthroplasty (TKA) rotational alignment and how best to obtain and measure it are debatable. The aim was to analyse the reliability of the Berger femoral, three different tibial and four different combined two-dimensional computer tomography (2D-CT) TKA component rotation measurements, and to ascertain which rotational values best predict a successful clinical outcome.

methodsThe 2D-CT scans were obtained post-operatively on 60 patients who had TKA. We determined one femoral [Berger's femoral angle (BFA)], three tibial [Berger's tibial angle (BTA), anatomical tibial angle (ATA) and bimalleolar posterior tibial component angle (BM_PTCA)] and four combined [transepicondylar posterior tibial component angle (TE_PTCA), bicondylar posterior tibial component angle (BC_PTCA, transepicondylar bimalleolar angle (TE_BM) and bicondylar bimalleolar angle (BC_BM)] TKA rotation angles. We made all measures in 23 patients twice by three observers and determined inter- and intra-observer agreement using the Bland-Altman plot method. We analysed measures of 55 patients using the area under the ROC curve (AUC) analysis to ascertain the discriminative capacity of BFA, ATA, TE_PTCA and BC_PTCA for predicting a successful clinical outcome according to the Knee Society Score (KSS) threshold.

resultsATA showed the smaller inter- and intra-observer average of differences (-0.1° and 1.6°, respectively) of the studied methods followed by BFA (-0.9° and 1.4°), TE_PTCA (-2.1° and 2.7°) and BC_PTCA (-0.5° and 1.8°). BFA (-4° to 2.1° and -6.1° to 8.8°) and BC_PTCA (-4.4° to 3.4° and -7.9° to 4.4°) showed the narrower inter- and intra-observer limits of agreement. A TKA device rotation (BC_PTCA) < 0.8° of external rotation (ER) predicted a KSS and KSS knee successful outcome, and < 3.8° ER for KSS functional (AUC = 0.889; 0.907 and 0.764, respectively). BFA and ATA < 0.9° ER and < 3.9° internal rotation (IR) predicted a successful KSS knee outcome (AUC = 0.796 and 0.889, respectively).

conclusionThe ATA tibial component rotation measurement was the most reliable of those studied. BFA, TE_PTCA and BC_PTCA were reliable measures for TKA femoral and combined rotation. The presence of a minimal rotation between the TKA components (BC_PTCA) and a small femoral ER or tibial IR predicted a successful KSS outcome. LEVEL OF EVIDENCE II:

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisOsteoarthritis, KneeFemurHumansKnee JointReproducibility of ResultsTibiaObserver variationReproducibility of resultsROC curveRotational alignmentTomographyTotal knee arthroplastyX-ray computed

Identifiers

PMID37535276
PMCPMC10400495

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.