Evidence map›Paper›PMID 37533604›Full record

ArticleACS applied engineering materials2023

Industrial Graphene Coating of Low-Voltage Copper Wires for Power Distribution.

Neeraj Mishra, Ylea Vlamidis, Leonardo Martini, Arianna Lanza, Zewdu M Gebeyehu, Alex Jouvray, Marco La Sala, Mauro Gemmi, Vaidotas Mišeikis, Matthew Perry and 3 more

Open access · hybridAbstract read
In one paragraph

Article in ACS applied engineering materials, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.9field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 9 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors at 2 institutions in 2 countries.

Neeraj MishraCenter for Nanotechnology Innovation@NEST, Istituto Italiano di Tecnologia, Piazza San Silvestro, 12, 56126 Pisa, Italy.ORCID https://orcid.org/0000-0002-7740-9168
Ylea VlamidisCenter for Nanotechnology Innovation@NEST, Istituto Italiano di Tecnologia, Piazza San Silvestro, 12, 56126 Pisa, Italy.
Leonardo MartiniCenter for Nanotechnology Innovation@NEST, Istituto Italiano di Tecnologia, Piazza San Silvestro, 12, 56126 Pisa, Italy.ORCID https://orcid.org/0000-0001-9669-1480
Arianna LanzaCenter for Nanotechnology Innovation@NEST, Istituto Italiano di Tecnologia, Piazza San Silvestro, 12, 56126 Pisa, Italy.ORCID https://orcid.org/0000-0002-7820-907X
Zewdu M GebeyehuCenter for Nanotechnology Innovation@NEST, Istituto Italiano di Tecnologia, Piazza San Silvestro, 12, 56126 Pisa, Italy.ORCID https://orcid.org/0000-0001-6451-6100
Alex JouvrayAIXTRON Ltd., Anderson Road, Swavesey, Cambridge CB24 4FQ, United Kingdom.
Marco La SalaBaldassari Cavi, Viale Europa 118/120, 55013 Capannori (Lucca), Italy.
Mauro GemmiCenter for Nanotechnology Innovation@NEST, Istituto Italiano di Tecnologia, Piazza San Silvestro, 12, 56126 Pisa, Italy.ORCID https://orcid.org/0000-0001-9542-3783
Vaidotas MišeikisCenter for Nanotechnology Innovation@NEST, Istituto Italiano di Tecnologia, Piazza San Silvestro, 12, 56126 Pisa, Italy.
Matthew PerryAIXTRON Ltd., Anderson Road, Swavesey, Cambridge CB24 4FQ, United Kingdom.
Kenneth B K TeoAIXTRON Ltd., Anderson Road, Swavesey, Cambridge CB24 4FQ, United Kingdom.
Stiven FortiCenter for Nanotechnology Innovation@NEST, Istituto Italiano di Tecnologia, Piazza San Silvestro, 12, 56126 Pisa, Italy.ORCID https://orcid.org/0000-0002-8939-3175
Camilla ColettiCenter for Nanotechnology Innovation@NEST, Istituto Italiano di Tecnologia, Piazza San Silvestro, 12, 56126 Pisa, Italy.ORCID https://orcid.org/0000-0002-8134-7633
Italian Institute of Technology · ITAixtron (United Kingdom) · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Copper (Cu) is the electrical conductor of choice in many categories of electrical wiring, with household and building installation being the major market of this metal. This work demonstrates the coating of Cu wires-with diameters relevant for low-voltage (LV) applications-with graphene. The chemical vapor deposition (CVD) coating process is rapid, safe, scalable, and industrially compatible. Graphene-coated Cu wires display good oxidation resistance and increased electrical conductivity (up to 1% immediately after coating and up to 3% after 24 months), allowing for wire diameter reduction and thus significant savings in wire production costs. Combined spectroscopic and diffraction analysis indicates that the conductivity increase is due to a change in Cu crystallinity induced by the coating process conditions, while electrical testing of aged wires shows that graphene plays a major role in maintaining improved electrical performances over long periods of time. Finally, graphene coating of Cu wires using an ambient-pressure roll-to-roll (R2R) CVD reactor is demonstrated. This enables the in-line production of graphene-coated metallic wires as required for industrial scale-up.

Identifiers

PMID37533604
PMCPMC10391742
OpenAlexW4379054453

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.