ArticleEuropean radiology2024
Deep learning reconstruction CT for liver metastases: low-dose dual-energy vs standard-dose single-energy.
Article in European radiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
26 citing papers in PubMed, 1 synthesis or guideline pooled it, 43 citations in OpenAlex.
- Dual-energy CT applications on liver imaging: what radiologists and radiographers should know? A systematic review.Abdominal radiology (New York) · 2024Pooled it
- Colorectal Cancer: Epidemiology, Risk Factors, Signaling Pathways, Clinical Features, Screening, Diagnosis, and Management.MedComm · 2026Review
- Conspicuity and characterization of pre-selected hypodense hepatic lesions in pancreatic cancer patients: limited clinical value of dual-energy portal phase CT.Abdominal radiology (New York) · 2026Article
- Deep learning image reconstruction improves visualization of arterial phase hyperenhancement and washout appearance on dual-energy CT for hepatocellular carcinoma: a non-inferiority study.Abdominal radiology (New York) · 2026Article
- The impact of a novel deep learning reconstruction algorithm on image quality in ultralow-dose CT: a quantitative phantom study.European radiology experimental · 2026Article
- Improving image quality and diagnostic confidence for PRETEXT staging in pediatric hepatoblastoma using thin-slice and low-energy virtual monochromatic images in dual-energy CT with deep learning image reconstruction algorithm.BMC medical imaging · 2026Article
- Photon-Counting Detector CT Allows Abdominal Virtual Monoenergetic Imaging at Lower Kiloelectron Volt Level with Lower Noise Using Lower Radiation Dose: A Prospective Matched Study Compared to Energy-Integrating Detector CT.Journal of imaging informatics in medicine · 2026Article
- Multi-institutional study for comparison of detectability of hypovascular liver metastases between 70- and 40-keV images: DELMIO study.Abdominal radiology (New York) · 2026Article
- Quantitative evaluation of a deep learning-based noise reduction algorithm in digital radiography using noise power spectrum analysis.Journal of applied clinical medical physics · 2026Article
- Effect of Deep Learning-Based Image Reconstruction on Lesion Conspicuity of Liver Metastases in Pre- and Post-contrast Enhanced Computed Tomography.Journal of imaging informatics in medicine · 2026Article
- Artificial intelligence in imaging diagnosis of liver tumors: current status and future prospects.Abdominal radiology (New York) · 2026Review
- Artificial intelligence (AI) and CT in abdominal imaging: image reconstruction and beyond.Abdominal radiology (New York) · 2026Review
- Diagnostic value of dual-energy CT virtual monochromatic imaging for supraspinatus tendon injuries: a comparison with standard CT and MRI.European radiology · 2025Article
- Impact of a deep learning image reconstruction algorithm on the robustness of abdominal computed tomography radiomics features using standard and low radiation doses.Quantitative imaging in medicine and surgery · 2025Article
- Image quality assessment of artificial intelligence iterative reconstruction for low dose unenhanced abdomen: comparison with hybrid iterative reconstruction.Abdominal radiology (New York) · 2025Observational
- Ultra-High-Resolution Photon-Counting Detector CT Benefits Visualization of Abdominal Arteries: A Comparison to Standard-Reconstruction.Journal of imaging informatics in medicine · 2025Article
- Deep learning reconstruction enhances tophus detection in a dual-energy CT phantom study.Scientific reports · 2025Article
- Opportunities for Artificial Intelligence in Operational Medicine: Lessons from the United States Military.Bioengineering (Basel, Switzerland) · 2025Review
- The Usefulness of Low-Kiloelectron Volt Virtual Monochromatic Contrast-Enhanced Computed Tomography with Deep Learning Image Reconstruction Technique in Improving the Delineation of Pancreatic Ductal Adenocarcinoma.Journal of imaging informatics in medicine · 2025Article
- Impact of deep learning reconstructions on image quality and liver lesion detectability in dual-energy CT: An anthropomorphic phantom study.Medical physics · 2025Article
Corrections and comments
- Commented on by
Authors and funding
11 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesTo assess image quality and liver metastasis detection of reduced-dose dual-energy CT (DECT) with deep learning image reconstruction (DLIR) compared to standard-dose single-energy CT (SECT) with DLIR or iterative reconstruction (IR).
methodsIn this prospective study, two groups of 40 participants each underwent abdominal contrast-enhanced scans with full-dose SECT (120-kVp images, DLIR and IR algorithms) or reduced-dose DECT (40- to 60-keV virtual monochromatic images [VMIs], DLIR algorithm), with 122 and 106 metastases, respectively. Groups were matched by age, sex ratio, body mass index, and cross-sectional area. Noise power spectrum of liver images and task-based transfer function of metastases were calculated to assess the noise texture and low-contrast resolution. The image noise, signal-to-noise ratios (SNR) of liver and portal vein, liver-to-lesion contrast-to-noise ratio (LLR), lesion conspicuity, lesion detection rate, and the subjective image quality metrics were compared between groups on 1.25-mm reconstructed images.
resultsCompared to 120-kVp images with IR, 40- and 50-keV VMIs with DLIR showed similar noise texture and LLR, similar or higher image noise and low-contrast resolution, improved SNR and lesion conspicuity, and similar or better perceptual image quality. When compared to 120-kVp images with DLIR, 50-keV VMIs with DLIR had similar low-contrast resolution, SNR, LLR, lesion conspicuity, and perceptual image quality but lower frequency noise texture and higher image noise. For the detection of hepatic metastases, reduced-dose DECT by 34% maintained observer lesion detection rates.
conclusionDECT assisted with DLIR enables a 34% dose reduction for detecting hepatic metastases while maintaining comparable perceptual image quality to full-dose SECT. CLINICAL RELEVANCE STATEMENT: Reduced-dose dual-energy CT with deep learning image reconstruction is as accurate as standard-dose single-energy CT for the detection of liver metastases and saves more than 30% of the radiation dose. KEY POINTS: • The 40- and 50-keV virtual monochromatic images (VMIs) with deep learning image reconstruction (DLIR) improved lesion conspicuity compared with 120-kVp images with iterative reconstruction while providing similar or better perceptual image quality. • The 50-keV VMIs with DLIR provided comparable perceptual image quality and lesion conspicuity to 120-kVp images with DLIR. • The reduction of radiation by 34% by DLIR in low-keV VMIs is clinically sufficient for detecting low-contrast hepatic metastases.
Indexed as