Evidence map›Paper›PMID 37531575›Full record

SynthesisThe Cochrane database of systematic reviews2023

Expanded polytetrafluoroethylene (ePTFE)-covered stents versus bare stents for transjugular intrahepatic portosystemic shunt in people with liver cirrhosis.

Peng Zhu, Sitong Dong, Ping Sun, Ajay P Belgaumkar, Yi Sun, Xiang Cheng, Qichang Zheng, Tong Li

Open access · greenAbstract readSystematic Review
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed, 1 pooled it
2.4field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 1 synthesis or guideline pooled it, 13 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Article
  4. Article
  5. Therapeutic Repair of Sperm Quality Decline Caused by Polytetrafluoroethylene.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025
    Article
  6. Impact of Polymer Coverings on the Corrosion Resistance of Nitinol.Shape memory and superelasticity : advances in science and technology · 2025
    Article
  7. Article
  8. High-performance automated abstract screening with large language model ensembles.Journal of the American Medical Informatics Association : JAMIA · 2025
    Article
  9. Article
  10. Drainage of ascites in cirrhosis.World journal of hepatology · 2024
    Review
  11. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 5 institutions in 2 countries.

Peng ZhuDepartment of Gastrointestinal Surgery, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China.
Sitong DongDivision of Psychiatry and Applied Psychology, School of Medicine, University of Nottingham, Nottingham, UK.
Ping SunDepartment of Hepatobiliary Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Ajay P BelgaumkarDepartment of Upper GI Surgery, Ashford and St Peter's NHS Trust, Chertsey, UK.
Yi SunSchool of Public Health, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Xiang ChengDepartment of Hepatobiliary Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Qichang ZhengDepartment of Hepatobiliary Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Tong LiDepartment of Gastrointestinal Surgery, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China.
Huazhong University of Science and Technology · CNSecond Affiliated Hospital of Chongqing Medical University · CNUnion Hospital · CNAshford and St Peter's Hospitals NHS Foundation Trust · GBUniversity of Nottingham · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTransjugular intrahepatic portosystemic shunt (TIPS) is a widely used procedure for management of uncontrolled upper gastrointestinal bleeding and refractory ascites in people with liver cirrhosis. However, nearly half of the people experience shunt dysfunction and recurrent symptoms within one year of the procedure. Expanded polytetrafluoroethylene (ePTFE)-covered stents are assumed to decrease shunt dysfunction by approximately 20% to 30%.

objectivesTo evaluate the benefits and harms associated with the use of expanded polytetrafluoroethylene (ePTFE)-covered stents versus bare stents in transjugular intrahepatic portosystemic shunts (TIPSs) for managing people with liver cirrhosis. SEARCH

methodsWe used standard, extensive Cochrane search methods. The latest search date was 28 February 2023. SELECTION CRITERIA: Randomised clinical trials comparing ePTFE-covered stents versus bare stents in TIPS for treatment of people with liver cirrhosis. DATA COLLECTION AND ANALYSIS: We used standard Cochrane methods. Our primary outcomes were 1. all-cause mortality, 2. procedure-related complications, and 3. health-related quality of life. Our secondary outcomes were 4. upper gastrointestinal bleeding, 5. recurrence of ascites, 6. hepatic encephalopathy, 7. kidney failure, 8. early thrombosis, 9. non-serious adverse events, and 10. shunt dysfunction. We used GRADE to assess certainty of evidence. We analysed outcome data at the maximum follow-up, except for the 'early thrombosis' outcome for which it was within 12 weeks after the TIPS procedure. MAIN

resultsWe included four trials with 565 randomised participants (age range: 18 to 75 years; male range: 63.6% to 75.0%). A total of 527 participants provided data for analyses because of losses to follow-up. Two trials were conducted in China; one in France; and one in France, Spain, and Canada. Participants were classified with cirrhosis Child-Pugh class A, B, or C, and for some, the class was not reported. We used intention-to-treat principle (four trials) and per-protocol analysis (one trial) to meta-analyse the data. One trial compared ePTFE-covered stents versus bare stents of the same diameter and three trials compared ePTFE-covered stents versus stents of different diameters. ePTFE-covered stents versus bare stents of the same diameter One trial with 258 participants compared 8 mm covered stent versus 8 mm bare stent. Mortality in the covered stent group is possibly lower than in the bare stent group (risk ratio (RR) 0.63, 95% confidence interval (CI) 0.43 to 0.92; low-certainty evidence). Upper gastrointestinal bleeding (RR 0.54, 95% CI 0.35 to 0.84), recurrence of ascites (RR 0.42, 95% CI 0.20 to 0.87), and shunt dysfunction (RR 0.42, 95% CI 0.28 to 0.61) occurred more often in the bare stent group than in the covered stent group (all low-certainty evidence). There was no difference in hepatic encephalopathy between groups (RR 1.10, 95% CI 0.76 to 1.61; very low-certainty evidence). The trial did not report data on procedure-related complications, health-related quality of life, early thrombosis, and segmental liver ischaemia (a non-serious adverse event). ePTFE-covered stents versus bare stents of different stent diameters Three trials compared ePTFE-covered stents versus bare stents of different diameters (10.5 (standard deviation (SD) 0.9) mm versus 11.7 (SD 0.8) mm; 8 mm versus 10 mm; and one trial used 10-mm stents that could be dilated from 8 mm to 10 mm). There was no evidence of a difference between the ePTFE-covered stents versus bare stents groups in mortality (RR 0.75, 95% CI 0.48 to 1.16; 3 trials, 269 participants), procedure-related complications (RR 0.53, 95% CI 0.05 to 5.57; 1 trial, 80 participants), upper gastrointestinal bleeding (RR 0.46, 95% CI 0.15 to 1.38; 3 trials, 269 participants), hepatic encephalopathy (RR 0.93, 95% CI 0.66 to 1.30; 3 trials, 269 participants), and kidney failure (RR 7.59, 95% CI 0.40 to 143.92; 1 trial, 121 participants) (all very low-certainty evidence). Recurrence of ascites (RR 0.30, 95% CI 0.11 to 0.85; 3 trials, 269 participants; low-certainty evidence), shunt dysfunction (RR 0.50, 95% CI 0.28 to 0.92; 3 trials, 269 participants; low-certainty evidence), and early thrombosis (RR 0.28, 95% CI 0.09 to 0.82; I AUTHORS'

conclusionsBased on the small number of trials with insufficient sample size and events, and study limitations, we assessed the overall certainty of evidence in the predefined outcomes as low or very low. Therefore, we are uncertain which of the two interventions (ePTFE-covered stents or bare stents of the same diameter and ePTFE-covered stents versus bare stents of different stent diameters) is effective for the evaluated outcomes. None of the four trials reported data on health-related quality of life, and data on complications were either missing or rarely reported. We lack high-quality trials to evaluate the role of ePTFE-covered stents for TIPS for managing people with liver cirrhosis.

Indexed as

Hepatic EncephalopathyPortasystemic Shunt, Transjugular IntrahepaticAdolescentAdultAgedAscitesFemaleGastrointestinal HemorrhageHumansLiver CirrhosisMaleMiddle AgedPolytetrafluoroethyleneQuality of LifeRandomized Controlled Trials as TopicStentsPolytetrafluoroethylene

Identifiers

PMID37531575
PMCPMC10400379
OpenAlexW4385481291

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.