Evidence map›Paper›PMID 37530905›Full record

ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2024

Circular external fixation for revision of failed tibia internal fixation.

Yousef Marwan, Jeffrey Turner, Rahul Senan, Ross Muir, Elizabeth Barron, Yvonne Hadland, Elizabeth Moulder, Hemant Sharma

Abstract read
PubMed Publisher
In one paragraph

Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.9field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 2 countries.

Yousef MarwanDepartment of Surgery, College of Medicine, Health Sciences Centre, Kuwait University, Kuwait City, Kuwait. yousefmarwan@hotmail.com.
Jeffrey TurnerLimb Reconstruction Unit, Department of Trauma and Orthopaedic Surgery, Hull University Teaching Hospitals, Hull, UK.
Rahul SenanLimb Reconstruction Unit, Department of Trauma and Orthopaedic Surgery, Hull University Teaching Hospitals, Hull, UK.
Ross MuirLimb Reconstruction Unit, Department of Trauma and Orthopaedic Surgery, Hull University Teaching Hospitals, Hull, UK.
Elizabeth BarronLimb Reconstruction Unit, Department of Trauma and Orthopaedic Surgery, Hull University Teaching Hospitals, Hull, UK.
Yvonne HadlandLimb Reconstruction Unit, Department of Trauma and Orthopaedic Surgery, Hull University Teaching Hospitals, Hull, UK.
Elizabeth MoulderLimb Reconstruction Unit, Department of Trauma and Orthopaedic Surgery, Hull University Teaching Hospitals, Hull, UK.
Hemant SharmaLimb Reconstruction Unit, Department of Trauma and Orthopaedic Surgery, Hull University Teaching Hospitals, Hull, UK.
University of Hull · GBKuwait University · KW

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe management of failed tibial fracture fixation remains a challenge for orthopaedic surgeons. This study investigate the utility and outcomes of circular external fixation in the management of failed internal fixation of tibial fractures.

methodsRetrospective review of a prospectively collected database of a complex limb reconstruction unit at a major trauma centre was done during December 2022. Patients with failed internal fixation of tibial fracture who underwent revision surgery with circular external fixation frame were included.

results20 patients with a mean age of 47.8 ± 16.5 years (range: 15-69) were included. Fourteen (70.0%) patients had failed plate and screws fixations, and the remaining six (30.0%) failed intramedullary nail fixation. The most common indication for revision surgery was development of early postoperative surgical site infection (5 patients; 25.0%). The mean duration of frame treatment was 199.5 ± 80.1 days (range = 49-364), while the mean follow-up duration following frame removal was 3.2 ± 1.8 years (range = 2-8). The overall union rate in this series was 100%; and all infected cases had complete resolution from infection. The total number of complications was 11, however, only two complications required surgical intervention. The most common complications reported were pin site infection (6; 30.0%) and limb length discrepancy of 2 cm (2; 10.0%).

conclusionsCircular external fixation is a reliable surgical option in the treatment of failed internal fixation of tibia fractures. This technique can provide limb salvage in complex infected and noninfected cases with a high union rate and minimal major complications.

Indexed as

TibiaTibial FracturesAdultExternal FixatorsFracture FixationFracture Fixation, InternalHumansMiddle AgedRetrospective StudiesTreatment OutcomeExternal fixationHexapodIlizarovInternal fixationMalreductionMalunionNonunionTibia

Identifiers

PMID37530905
OpenAlexW4385476100

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.