Validity of leg length measurement in the supine and standing position compared with pelvic survey X-ray after total hip arthroplasty.

Steffen Brodt, Marcel Schulze, Benjamin Jacob, Georgi Wassilew, Dimitri Nowack, Sebastian Rohe, Georg Matziolis

Abstract read
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Steffen Brodt *Department of Orthopedics, Jena University Hospital, Campus Eisenberg, Klosterlausnitzer Str. 81, 07607, Eisenberg, Germany. s.brodt@krankenhaus-eisenberg.de.ORCID http://orcid.org/0000-0003-1286-8766
Marcel Schulze *Department of Orthopedics, Jena University Hospital, Campus Eisenberg, Klosterlausnitzer Str. 81, 07607, Eisenberg, Germany.
Benjamin JacobDepartment of Orthopedics, Jena University Hospital, Campus Eisenberg, Klosterlausnitzer Str. 81, 07607, Eisenberg, Germany.
Georgi WassilewCenter for Orthopaedics, Trauma Surgery and Rehabilitation Medicine, University Medicine Greifswald, Ferdinand-Sauerbruch-Straße, 17475, Greifswald, Germany.
Dimitri NowackDepartment of Orthopedics, Jena University Hospital, Campus Eisenberg, Klosterlausnitzer Str. 81, 07607, Eisenberg, Germany.
Sebastian RoheDepartment of Orthopedics, Jena University Hospital, Campus Eisenberg, Klosterlausnitzer Str. 81, 07607, Eisenberg, Germany.
Georg MatziolisDepartment of Orthopedics, Jena University Hospital, Campus Eisenberg, Klosterlausnitzer Str. 81, 07607, Eisenberg, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe correct adjustment of leg length is a major goal in the implantation of total hip replacements (THRs). Differences in leg length can lead to functional impairment and patient dissatisfaction. By determining leg length at an early stage, before the patient is discharged from hospital, compensatory measures such as the production of special insoles or orthopaedic footwear can be initiated promptly if there is a difference in leg length. Due to shortening of the period of time spent in hospital, the traditional measurement of leg length in a standing position may be increasingly subject to error. A protective posture immediately after surgery or the presence of a twisted pelvis, for example, due to scoliotic spinal misalignments, falsifies the measurement result in the standing position. Here, the measurement of leg length in the supine position may prove to be accurate immediately postoperatively, regardless of potential sources of error, and is to be compared with measurement in the standing position versus radiological measurement on the AP pelvic survey. MATERIAL AND

methodsThe present retrospective study included 190 patients who had undergone primary total hip arthroplasty. The leg length difference (LLD) of the patients was determined pre- and postoperatively both in the supine and standing position and compared with the postoperative radiological pelvic survey image.

resultsPostoperatively, it was shown that the mean length measured was 0.35 mm too long in the supine position and 0.68 mm too short in the standing position (p value < 0.001). Determination of the average absolute measurement error produces a deviation of 4.06 mm in the standing and 4.51 mm in the supine position (p value 0.126).

conclusionsIt is shown that the postoperative measurement of LLD in the supine and standing position is equally valid and sufficiently accurate, compared with the gold standard of measurement on a radiograph.

Indexed as

Arthroplasty, Replacement, HipHumansLegRetrospective StudiesStanding PositionSupine PositionX-RaysLeg length differenceLimb length measurementTechniqueTotal hip arthroplasty

Identifiers

PMID37530843
PMCPMC10774217

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.