Evidence map›Paper›PMID 37529685›Full record

ArticleHardwareX2023

Microfluidic paper-based device coupled with 3D printed imaging box for colorimetric detection in resource-limited settings.

Vijay Vaishampayan, Oinam Robita Chanu, Balasubramanian Sivasamy, Muthamilselvi Ponnuchamy, Varshini Karthik, Ambar Pendharkar, Lohith Srinivas Thotakura, Aryan Prabhu, Venkatesan Dhananjeyan, Ashish Kapoor

Abstract read
In one paragraph

Article in HardwareX, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Vijay VaishampayanDepartment of Chemical Engineering, Indian Institute of Technology, Ropar, Rupnagar, Punjab 140001, India.
Oinam Robita ChanuDepartment of Biomedical Engineering, SRM Institute of Science and Technology, Kattankulathur, Tamil Nadu 603203, India.
Balasubramanian SivasamyDepartment of Chemical Engineering, KPR Institute of Engineering and Technology, Coimbatore, Tamil Nadu 641407, India.
Muthamilselvi PonnuchamyDepartment of Chemical Engineering, SRM Institute of Science and Technology, Kattankulathur, Tamil Nadu 603203, India.
Varshini KarthikDepartment of Biomedical Engineering, SRM Institute of Science and Technology, Kattankulathur, Tamil Nadu 603203, India.
Ambar PendharkarDepartment of Chemical Engineering, SRM Institute of Science and Technology, Kattankulathur, Tamil Nadu 603203, India.
Lohith Srinivas ThotakuraDepartment of Chemical Engineering, SRM Institute of Science and Technology, Kattankulathur, Tamil Nadu 603203, India.
Aryan PrabhuDepartment of Chemical Engineering, SRM Institute of Science and Technology, Kattankulathur, Tamil Nadu 603203, India.
Venkatesan DhananjeyanDepartment of Chemical Engineering, Sathyabama Institute of Science and Technology, Chennai, Tamil Nadu 600119, India.
Ashish KapoorDepartment of Chemical Engineering, Harcourt Butler Technical University, Kanpur, Uttar Pradesh 208002, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Rapid and effective methods for the detection of analytes such as water contaminants, food adulterants and biomolecules are essential for the protection of public health and environmental protection. Most of the currently established analytical techniques need sophisticated equipment, centralized testing facilities, costly operations, and trained personnel. Such limitations make them inaccessible to the general populace, particularly in regions with limited resources. The emergence of microfluidic devices offers a promising alternative to overcome several such constraints. This work describes a protocol for fabricating a low-cost, open-source paper-based microfluidic device using easily available tools and materials for colorimetric detection of analytes. The ease and simplicity of fabrication allow users to design customized devices. The device is coupled with an imaging box assembled from 3D printed parts to maintain uniform lighting conditions during analytical testing. The platform allows digital imaging using smartphones or cameras to instantaneously capture images of reaction zones on the device for quantitative analysis. The system is demonstrated for detecting hexavalent chromium, a toxic water contaminant. The image analysis is performed using open-source ImageJ for quantification of results. The approach demonstrated in this work can be readily adopted for a wide range of sensing applications.

Indexed as

3D PrintingColorimetric detectionImaging boxPaper-based devicesSensor

Identifiers

PMID37529685
PMCPMC10387609

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.