Evidence map›Paper›PMID 37529510›Full record

ArticleCureus2023

Comparative Evaluation of Distortion in Wax Patterns Fabricated Using Conventional and Electrical Heat Sources: An In Vitro Study.

BarathSundar A, Saravanan M, Muthukumar B

Abstract read
In one paragraph

Article in Cureus, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

BarathSundar AProsthodontics, SRM Dental College, Chennai, IND.
Saravanan MProsthodontics, SRM Dental College, Chennai, IND.
Muthukumar BProsthodontics, SRM Dental College, Chennai, IND.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction Tooth loss significantly impacts individuals' functional capabilities and quality of life. Fixed partial dentures have been a reliable treatment method for tooth replacement, with their fabrication often involving waxes. Waxes play a crucial role in creating a wax pattern in dental restoration; in particular, inlay waxes play a role in the shape, size, and contour of the restorations. However, these waxes have inherent disadvantages, including a high thermal expansion coefficient and propensity to warp or distort over time. This study aimed to compare wax patterns derived from two heat sources, an electric heat source and a conventional flame, to enhance their marginal accuracy and dimensional stability. Methods This study used an abutment resembling a prepared maxillary right central incisor designed via computer-aided design software and milled from zirconia. Inlay wax was melted using either an electrically heated spatula or a conventional flame, poured into a metal sleeve or a cuboidal mold, and allowed to cool to room temperature. The wax patterns were stored at room temperature for one hour and 24 hours. Subsequently, linear and volumetric measurements were taken to assess the shrinkage of the wax patterns. Results Patterns fabricated using the electric heat source showed less shrinkage at both time points for linear shrinkage and at one hour for volumetric shrinkage than those made using the conventional flame. However, by the 24th hour, patterns made with the electric heat source showed more volumetric shrinkage than those made with the conventional heat source. Significant shrinkage was observed between one hour and 24 hours for both heat sources, suggesting that wax patterns should be invested immediately after fabrication for maximum precision. Conclusions The results suggest that electric heating may be a viable alternative to conventional flame for minimizing discrepancies in wax patterns, particularly in the initial stages of wax pattern fabrication. However, prolonged use may lead to greater volumetric shrinkage with electric heating. These findings point to the potential of electric heating as an alternative to conventional flame in dental restorations, although further research is needed to validate and expand upon these findings.

Indexed as

dental restorationdimensional stabilitydistortioninlay waxeslinear shrinkagemarginal accuracywax pattern fabrication

Identifiers

PMID37529510
PMCPMC10388666

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.