Evidence map›Paper›PMID 37528475›Full record

ArticleArthroplasty (London, England)2023

Arithmetic hip knee angle measurement on long leg radiograph versus computed tomography-inter-observer and intra-observer reliability.

Tom Jan Gieroba, Sofia Marasco, Sina Babazadeh, Claudia Di Bella, Dirk van Bavel

Abstract read
In one paragraph

Article in Arthroplasty (London, England), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Tom Jan GierobaDepartment of Orthopaedics, St Vincent's Hospital Melbourne, Fitzroy, VIC, 3065, Australia. tom.gieroba@adelaide.edu.au.ORCID http://orcid.org/0000-0002-1789-8211
Sofia MarascoDepartment of Orthopaedics, St Vincent's Hospital Melbourne, Fitzroy, VIC, 3065, Australia.
Sina BabazadehDepartment of Orthopaedics, St Vincent's Hospital Melbourne, Fitzroy, VIC, 3065, Australia.
Claudia Di BellaDepartment of Orthopaedics, St Vincent's Hospital Melbourne, Fitzroy, VIC, 3065, Australia.
Dirk van BavelDepartment of Orthopaedics, St Vincent's Hospital Melbourne, Fitzroy, VIC, 3065, Australia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPre-operative alignment is important for knee procedures including total knee arthroplasty (TKA), especially when considering alternative alignments. The arithmetic Hip Knee Angle (aHKA) is a measure of coronal alignment calculated using the medial proximal tibial (MPTA) and lateral distal femoral angles (LDFA). Traditionally, aHKA is measured on long leg radiographs (LLR). This study assesses the reproducibility of aHKA measurement on LLR and robotic-assisted TKA planning CT.

methodsSixty-eight TKA patients with pre-operative LLR and planning CTs were included. Three observers measured the LDFA, MPTA and aHKA three times on each modality and intra-observer and inter-observer reliability was calculated. Statistical analysis was undertaken with Pearson's r and the Bland-Altman test.

resultsMean intra-observer coefficient of repeatability (COR) for LLR vs. CT: MPTA 3.50° vs. 1.73°, LDFA 2.93° vs. 2.00° and aHKA 2.88° vs. 2.57° for CT. Inter-observer COR for LLR vs. CT: MPTA 2.74° vs. 1.28°, LDFA 2.31° vs. 1.92°, aHKA 3.56° vs. 2.00°. Mean intra-observer Pearson's r for MPTA was 0.93 for LLR and 0.94 for CT, LDFA 0.90 for LLR and 0.91 for CT and aHKA 0.92 for LLR and 0.94 for CT. Inter-observer Pearson's r for LLR compared to CT: MPTA 0.93 vs. 0.97, LDFA 0.91 vs. 0.90, aHKA 0.91 and 0.95.

conclusionWhen compared to LLR, CT measurements of MPTA, LDFA and aHKA are more reproducible and have a good correlation with LLR measurement. CT overcomes difficulties with positioning, rotation, habitus and contractures when assessing coronal plane alignment and may obviate the need for LLRs.

Indexed as

Arithmetic HKA (aHKA)KneeKnee alignmentRobotic arthroplastyTotal knee arthroplasty

Identifiers

PMID37528475
PMCPMC10394810

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.