Evidence map›Paper›PMID 37528074›Full record

ArticleSpinal cord series and cases2023

The temporal burden of preparing catheters for re-use in adults with spinal cord injury: a cross-sectional study.

T Miller, L J Roik, T Kalimullina, S Samejima, C Shackleton, R N Malik, R Sachdeva, A V Krassioukov

Open access · greenAbstract read
In one paragraph

Article in Spinal cord series and cases, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.5field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

T MillerInternational Collaboration on Repair Discoveries, Faculty of Medicine, University of British Columbia, Vancouver, BC, Canada.ORCID 0000-0001-5675-2824
L J RoikInternational Collaboration on Repair Discoveries, Faculty of Medicine, University of British Columbia, Vancouver, BC, Canada.
T KalimullinaInternational Collaboration on Repair Discoveries, Faculty of Medicine, University of British Columbia, Vancouver, BC, Canada.
S SamejimaInternational Collaboration on Repair Discoveries, Faculty of Medicine, University of British Columbia, Vancouver, BC, Canada.
C ShackletonInternational Collaboration on Repair Discoveries, Faculty of Medicine, University of British Columbia, Vancouver, BC, Canada.
R N MalikInternational Collaboration on Repair Discoveries, Faculty of Medicine, University of British Columbia, Vancouver, BC, Canada.
R SachdevaInternational Collaboration on Repair Discoveries, Faculty of Medicine, University of British Columbia, Vancouver, BC, Canada.
A V KrassioukovInternational Collaboration on Repair Discoveries, Faculty of Medicine, University of British Columbia, Vancouver, BC, Canada. andrei.krassioukov@vch.ca.ORCID 0000-0002-0022-7972
University of British Columbia · CAVancouver Coastal Health · CA

Funding

CIHR
6 · The paper itself

Abstract

STUDY

designCross-sectional

objectivesNeurogenic lower urinary tract dysfunction is common among people with spinal cord injury (SCI). Although single-use clean intermittent catheterization is recommended to facilitate routine bladder emptying, catheter re-use is common. Barriers associated with the preparation (i.e., cleaning) of catheters for re-use are unknown. This study examined barriers to catheter re-use in adult individuals with SCI by assessing (1) the time needed to clean a catheter, and (2) the perceived difficulty of the catheter cleaning routine.

settingLaboratory

methodsTwenty individuals with chronic SCI ( ≥ 1 year since injury; Group 1 = 10 with tetraplegia; Group 2 = 10 with paraplegia) completed the study. Using a standardized cleaning procedure (i.e., Milton method), catheter cleaning was timed for each participant. Perceived difficulty was assessed using a 5-point Likert scale. Functional impairment was assessed with the Upper Extremity Motor Score (UEMS).

resultsSignificant between-group differences were observed for total cleaning time (Group 1 = 1584.1 ± 179.8 s; Group 2 = 1321.0 ± 93.8 s, p = 0.004) and perceived difficulty [Group 1 = 2.6 (2, 3); Group 2 = 2 (1.7, 2.3), p = 0.028]. Total cleaning time was significantly correlated with UEMS (ρ = -0.709, p ≤ 0.001) and perceived difficulty (ρ = 0.468, p = 0.037). UEMS emerged as an independent predictor of total cleaning time (R

conclusionsPreparing catheters for re-use is time-intensive and difficult for people with higher SCI level, severity and more pronounced upper limb motor impairment, which was independently associated with total cleaning time. Performing this routine on a consistent basis would require a substantial time commitment and would have a profoundly negative impact on overall quality of life.

Indexed as

Spinal Cord InjuriesUrinary Bladder, NeurogenicAdultCatheters, IndwellingCross-Sectional StudiesHumansQuality of Life

Identifiers

PMID37528074
PMCPMC10393987
OpenAlexW4385463303

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.